Short-term mechanical circulatory support for severe primary graft dysfunction following orthotopic heart transplant
Michal Hulman1, Panagiotis Artemiou1, Matej Ondrusek1
1Department of Cardiac Surgery, Medical Faculty of the Slovak Medical University, National Institute of Cardiovascular Diseases, Clinic of Cardiac Surgery, Bratislava, Slovakia.
Objectives:
Primary graft dysfunction (PGD) is a devastating complication and the most common cause of early death following a heart transplant. The goal of this study was to report our experience of using mechanical circulatory support to manage severe PGD.
Methods:
Following 208 heart transplants performed between January 2007 and May 2017, 14 (6.7%) patients presented with severe PGD. We provided haemodynamic support using the following approaches: a venoarterial extracorporeal membrane oxygenation device, left ventricular assist device, right ventricular assist device and biventricular assist device. Primary complications included severe PGD, which resulted in hospital deaths and late survival. The mean follow-up was 3.7 ± 2.7 years.
Results:
Fourteen (6.7%) heart transplant recipients presented with severe PGD. Seven patients received a venoarterial extracorporeal membrane oxygenation device; 1 patient received a left ventricular assist device; 4 patients received a right ventricular assist device; and 2 patients received a biventricular assist device. Mean device support and explantation times were 4.7 ± 2 and 6.3 ± 2 days, respectively. Weaning with cardiac recovery was successful in 57.1% of the patients. The hospital mortality rate was 50%. Postoperative causes of morbidity included renal failure that necessitated dialysis in 28.5%, surgical re-exploration due to postoperative bleeding in 57.1%, pneumonia in 28.5%, sepsis in 14.2%, sternal wound infection in 14.2% and mediastinitis in 7.1% of the patients, respectively. There were no deaths following hospital discharge or later follow-up appointments.
Conclusions:
Mechanical support devices such as venoarterial extracorporeal membrane oxygenation specifically offer a reliable therapeutic approach. Recognizing the relatively high number of deaths in-hospital, patients who have cardiac recovery and a successful hospital discharge can expect a favourable late outcome.
More Related Videos
08:15Innovative Strategies for Organ Preservation in Heart Transplantation: Uniform Cooling Preservation and Ex-situ Normothermic Perfusion
Published on: November 28, 2025
08:32Orthotopic Aortic Transplantation: A Rat Model to Study the Development of Chronic Vasculopathy
Published on: December 4, 2010
Related Concept Videos
Anatomy of the Circulatory System
Long-term Depression
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps:
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Anatomy of the Heart