Identification and quantification of human microcirculatory leukocytes using handheld video microscopes at the
Zühre Uz1,2, Thomas M van Gulik2, Mehtap D Aydemirli1
1Department of Translational Physiology, Academic Medical Center, University of Amsterdam , Amsterdam , The Netherlands.
Abstract:
Leukocyte recruitment and adhesion to the endothelium are hallmarks of systemic inflammation that manifest in a wide range of diseases. At present, no method is available to directly measure leukocyte kinetics at the bedside. In this study, we validate a new method to identify and quantify microcirculatory leukocytes observed by handheld vital microscopy (HVM) using space-time diagram (STD) analysis. Video clips ( n = 59) containing one capillary-postcapillary venule unit where leukocytes could be observed emanating from a capillary into a venule in cardiac surgery patients ( n = 20) were included. STD analysis and manual counting were used to quantify the number of leukocytes (total, rolling, and nonrolling). Pearson's correlation and Bland-Altman analysis were used to determine agreement between the STDs and manual counting. For reproducibility, intra- and interobserver coefficients of variation (CVs) were assessed. Leukocyte (rolling and nonrolling) and red blood cell velocities were assessed. The STDs and manual counting procedures for the quantification of rolling leukocytes showed good agreement ( r = 0.8197, P < 0.0001), with a Bland-Altman analysis mean difference of -0.0 (-6.56; 6.56). The overall intraobserver CV for the STD method was 1.5%. The overall interobserver CVs for the STD and the manual method were 5.6% and 9.4%, respectively. The nonrolling velocity was significantly higher than the rolling velocity (812 ± 519 µm/s vs. 201 ± 149 µm/s, P = 0.001). STD results agreed with the manual counting procedure results, had a better reproducibility, and could assess the leukocyte velocity. STD analysis using bedside HVM imaging presented a new methodology for quantifying leukocyte kinetics and functions in the microcirculation. NEW & NOTEWORTHY In this study, we introduce space-time diagram analysis of sublingual microcirculation imaging using handheld vital microscopy to identify and quantify the presence and kinetics of human microcirculatory leukocytes. We validated the methodology by choosing anatomical units consisting of a capillary connected to a venule, which allowed precise identification of leukocytes.
Related Concept Videos
Disorders of Leukocytes
Leukopenia may result from bone marrow disorders, autoimmune diseases, and infectious diseases. For example, conditions such as multiple myeloma and aplastic anemia can impair the bone marrow's ability to produce adequate leukocytes. Similarly, autoimmune diseases like lupus and viral infections such as HIV can prompt the immune...
Classification of Leukocytes
Neutrophils are the most abundant type of granular leukocytes, comprising 50-70% of all leukocytes. They feature small, evenly distributed granules and a...
Structure and Function of Leukocytes
White blood cells protect the body...
Microscopic Anatomy of Skeletal Muscles
The muscle sarcolemma is a plasma membrane enclosing each muscle cell that conducts electrical signals called action potentials. The sarcolemma extends into the cell to form T-tubules, ensuring the neural impulses are uniformly distributed across the entire muscle...
Methods of Classification and Identification
Endoscopic Procedures III: Video Capsule Endoscopy