An Experimental Study on Static and Dynamic Strain Sensitivity of Embeddable Smart Concrete Sensors Doped with Carbon

Andrea Meoni1, Antonella D'Alessandro2, Austin Downey3,4

  • 1Department of Civil and Environmental Engineering, University of Perugia, Perugia 06125, Italy. andrea.meoni@unipg.it.

Related Concept Videos

Static, Stagnation, Dynamic and Total Pressure01:24

Static, Stagnation, Dynamic and Total Pressure

The concept of static, stagnation, dynamic, and total pressure is fundamental in fluid dynamics, often explained using Bernoulli's equation:
1.6K
Dynamic Modulus of Elasticity of Concrete01:16

Dynamic Modulus of Elasticity of Concrete

The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
1.0K
Types of Non-structural Cracks in Concrete01:28

Types of Non-structural Cracks in Concrete

Non-structural cracks are primarily of three types: plastic, early-age thermal, and drying shrinkage cracks. Plastic cracks are further classified into plastic shrinkage cracks and plastic settlement cracks.
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
519
Carbon Skeletons01:12

Carbon Skeletons

Life on Earth is carbon-based, as all macromolecules that make up living organisms contain carbon atoms. All organic compounds have a carbon backbone. Each carbon atom is tetravalent and can bond with four other atoms, making it an extraordinarily flexible component of biological molecules. Because carbon’s valence electrons are stable, it rarely becomes an ion. As the carbon chain increases in length, structural modifications such as ring structures, double bonds, and branching side...
115.6K
Sputum Studies II: Culture and Sensitivity01:20

Sputum Studies II: Culture and Sensitivity

Description
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
1.3K
Static Equilibrium - I01:05

Static Equilibrium - I

A rigid body is said to be in dynamic equilibrium when both its linear and angular acceleration are zero, relative to an inertial frame of reference. This means that a body in equilibrium can be moving, but only when its linear and angular velocities are constant. A rigid body is said to be in static equilibrium when it is at rest in the selected frame of reference. The distinction between static equilibrium (e.g., a state of rest) and dynamic equilibrium (e.g, a state of uniform motion) is...
18.9K