Validation of a routine gas chromatography mass spectrometry method for 2-hydroxyglutarate quantification in human
Esther Fernández-Galán1, Núria Massana1, Marina Parra-Robert1
1Department of Biochemistry and Molecular Genetics, CDB, Hospital Clinic Universitari, c/ Villarroel 170, 08036 Barcelona, Spain.
Abstract:
High circulating levels of 2-hydroxyglutarate (2HG) have been reported in patients with determinate isocitrate dehydrogenase (IDH) mutated tumors. Recent studies indicate that in malignancies such as acute myeloid leukemia (AML), measurements of 2HG in serum provide useful diagnostic and prognostic information and improve patient selection and monitoring of IDH-targeted treatments. In the current study, we validated a sensitive and specific gas chromatography mass spectrometry (GC-MS) method specifically intended to quantify serum levels of 2HG in routine clinical laboratories. Extraction was liquid-liquid with ethyl acetate, and derivatization was reduced to 3 min of microwave irradiation. The analytical method was linear over a wide dynamic range, presenting acceptable intraday and day-to-day precision and accuracy. The limit of quantification was 10 ng/mL, process efficiency ranged between 38% and 49%, and recovery of added 2HG was 99-105%. 2HG was found to be stable in serum for up to 48 h at both 4 °C and at ambient temperature, and after three freeze-thaw cycles. Microwave derivatizated extracts in the autosampler were found to be stable for up to 120 h. In summary, the present method is useful for quantification of 2HG serum levels in patients with IDH mutated malignancies in clinical laboratories.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
07:21Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry GC-MS-based Metabolomics
Published on: June 6, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume