Related Experiment Video
Updated: Feb 13, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Reliability and correlation analysis of computed methods to convert conventional 2D radiological hindfoot
A Burssens1, J Peeters2, M Peiffer3
1Department of Orthopaedic Surgery, Ghent University Hospital, De Pintelaan 185, 9000, Ghent, Belgium. arne.burssens@ugent.be.
Purpose:
The exact radiographic assessment of the hindfoot alignment remains challenging. This is reflected in the different measurement methods available. Weightbearing CT (WBCT) has been demonstrated to be more accurate in hindfoot measurements. However, current measurements are still performed in 2D. This study wants to assess the use of computed methods to convert the former uniplanar hindfoot measurements obtained after WBCT towards a 3D setting.
Methods:
Forty-eight patients, mean age of 39.6 ± 13.2 years, with absence of hindfoot pathology were included. A WBCT was obtained, and images were subsequently segmented and analyzed using computer-aided design operations. In addition to the hindfoot angle (HA), other ankle and hindfoot parameters such as the anatomical tibia axis, talocalcaneal axis (TCA), talocrural angle, tibial inclination (TI), talar tilt, and subtalar vertical angle were determined in 2D and 3D.
Results:
The mean [Formula: see text] was [Formula: see text] of valgus ± 3.2 and the [Formula: see text] was [Formula: see text] of valgus ± 6.5. These angles differed significantly from each other with a [Formula: see text]. The correlation between both showed to be good by [Formula: see text] Pearson correlation coefficient (r) of 0.72 ([Formula: see text]). The [Formula: see text] showed to be excellent when compared to the [Formula: see text], which was good. Similar findings were obtained in other angles. The highest correlation was seen between the [Formula: see text] and [Formula: see text] (r = 0.83, [Formula: see text]) and an almost perfect agreement in the [Formula: see text] ([Formula: see text]).
Conclusion:
This study shows a good and reliable correlation between the [Formula: see text] and [Formula: see text]. However, the [Formula: see text] overcomes the shortcomings of inaccuracy and provides valuable spatial data that could be incorporated during computer-assisted surgery to assess the multiplanar correction of a hindfoot deformity.
Related Concept Videos
Radiological Investigation I: X-ray and CT
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
2D NMR: Overview of Heteronuclear Correlation Techniques
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
Reliability and Validity
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)