New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism
Carmen Canovas1, Aixa Alarcon1, Robert Rosén1
1From Implant Research and Development (Canovas, Alarcon, Rosén, Piers), Abbott Medical Optics, Inc., Groningen BV, the Netherlands; Clinical Research (Kasthurirangan), Abbott Medical Optics, Inc., Santa Ana, California, and Cullen Eye Institute (Koch), Baylor College of Medicine, Houston, Texas, USA; Department of Ophthalmology and Vision Science (Ma), University of Toronto, Toronto, Ontario, Canada.
Purpose:
To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA).
Setting:
Abbott Medical Optics, Inc., Groningen, the Netherlands.
Design:
Retrospective case report.
Methods:
In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates.
Results:
The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001).
Conclusions:
The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power.
More Related Videos
Related Concept Videos
Trial and Error and Algorithm
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating Standard Free Energy Changes
Calculating pH Changes in a Buffer Solution
Power
Numerical Calculations
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...