Radiation Exposure of Operators Performing Transesophageal Echocardiography During Percutaneous Structural Cardiac
James A Crowhurst1, Gregory M Scalia1, Mark Whitby2
1Cardiology Department, The Prince Charles Hospital, Chermside, Queensland, Australia; University of Queensland, St. Lucia, Queensland, Australia.
Background:
Transesophageal echocardiography operators (TEEOP) provide critical imaging support for percutaneous structural cardiac intervention procedures. They stand close to the patient and the associated scattered radiation.
Objectives:
This study sought to investigate TEEOP radiation dose during percutaneous structural cardiac intervention.
Methods:
Key personnel (TEEOP, anesthetist, primary operator [OP1], and secondary operator) wore instantly downloadable personal dosimeters during procedures requiring TEE support. TEEOP effective dose (E) and E per unit Kerma area product (E/KAP) were calculated. E/KAP was compared with C-arm projections. Additional shielding for TEEOP was implemented, and doses were measured for a further 50 procedures. Multivariate linear regression was performed to investigate independent predictors of radiation dose reduction.
Results:
In the initial 98 procedures, median TEEOP E was 2.62 μSv (interquartile range [IQR]: 0.95 to 4.76 μSv), similar to OP1 E: 1.91 μSv (IQR: 0.48 to 3.81 μSv) (p = 0.101), but significantly higher than secondary operator E: 0.48 μSv (IQR: 0.00 to 1.91 μSv) (p < 0.001) and anesthetist E: 0.48 μSv (IQR: 0.00 to 1.43 μSv) (p < 0.001). Procedures using predominantly right anterior oblique (RAO) and steep RAO projections were associated with high TEEOP E/KAP (p = 0.041). In a further 50 procedures, with additional TEEOP shielding, TEEOP E was reduced by 82% (2.62 μSv [IQR: 0.95 to 4.76] to 0.48 μSv [IQR: 0.00 to 1.43 μSv] [p < 0.001]). Multivariate regression demonstrated shielding, procedure type, and KAP as independent predictors of TEEOP dose.
Conclusion:
TEE operators are exposed to a radiation dose that is at least as high as that of OP1 during percutaneous cardiac intervention. Doses were higher with procedures using predominantly RAO projections. Radiation doses can be significantly reduced with the use of an additional ceiling-suspended lead shield.
Related Concept Videos
Operant Conditioning Intervention
In operant conditioning, behaviors that are...
Pathophysiology of Cardiac Performance
Biological Effects of Radiation
Structure of Cardiac Muscles
Compared to skeletal muscles, cardiac muscle cells are small and mostly have a single nucleus. Additionally, they are usually...
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions