Related Experiment Video
Updated: Feb 13, 2026

Fabrication and Characterization of Optical Tissue Phantoms Containing Macrostructure
Published on: February 12, 2018
Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient
Michael B Wayson1,2, Wesley E Bolch1
1J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States of America.
Abstract:
Various computational tools are currently available that facilitate patient organ dosimetry in diagnostic nuclear medicine, yet they are typically restricted to reporting organ doses to ICRP-defined reference phantoms. The present study, while remaining computational phantom based, provides straightforward tools to adjust reference phantom organ dose for both internal photon and electron sources. A wide variety of monoenergetic specific absorbed fractions were computed using radiation transport simulations for tissue spheres of varying size and separation distance. Scaling methods were then constructed for both photon and electron self-dose and cross-dose, with data validation provided from patient-specific voxel phantom simulations, as well as via comparison to the scaling methodology given in MIRD Pamphlet No. 11. Photon and electron self-dose was found to be dependent on both radiation energy and sphere size. Photon cross-dose was found to be mostly independent of sphere size. Electron cross-dose was found to be dependent on sphere size when the spheres were in close proximity, owing to differences in electron range. The validation studies showed that this dataset was more effective than the MIRD 11 method at predicting patient-specific photon doses for at both high and low energies, but gave similar results at photon energies between 100 keV and 1 MeV. The MIRD 11 method for electron self-dose scaling was accurate for lower energies but began to break down at higher energies. The photon cross-dose scaling methodology developed in this study showed gains in accuracy of up to 9% for actual patient studies, and the electron cross-dose scaling methodology showed gains in accuracy up to 9% as well when only the bremsstrahlung component of the cross-dose was scaled. These dose scaling methods are readily available for incorporation into internal dosimetry software for diagnostic phantom-based organ dosimetry.
More Related Videos
Related Concept Videos
Internal Anatomy of the Kidney
Anatomical Position and Dimensions
The kidneys are retroperitoneal organs positioned against the posterior abdominal wall on either side of the spine, roughly between the twelfth thoracic and third lumbar vertebrae. Each kidney is typically 10-12 cm long, 5-6 cm wide, and 3-4 cm thick, weighing about 150 grams.
Renal Cortex
The outermost region of the kidney is the...
International Nursing Organizations I
ICN member organizations work to advance the field of nursing and healthcare via policies, partnerships, lobbying, professional...
International Nursing Organizations II
The WHO provides expert team support, including funding, vaccines, testing, and treatment tools at the country level to fight...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Internal Energy
Internal Energy

