Related Experiment Video
Updated: Feb 13, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Helpful Only When Elevated: Initial Serum Lactate in Stable Emergency Department Patients with Sepsis Is Specific,
Shannon M Fernando1, Douglas P Barnaby2, Christophe L Herry3
1Department of Emergency Medicine, University of Ottawa, Ottawa, Ontario, Canada; Division of Critical Care, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Background:
Early emergency department (ED) identification of septic patients at risk of deterioration is critical. Lactate is associated with 28-day mortality in admitted patients, but little evidence exists on its use in predicting short-term deterioration.
Objective:
Our aim was to determine the role of initial serum lactate for prediction of short-term deterioration in stable ED patients with suspected sepsis.
Methods:
We conducted a prospective cohort study of adult ED sepsis patients. Venous lactate was obtained within 2 h of ED arrival. Main outcome was subsequent deterioration (defined as any of the following: death, intensive care admission > 24 h, intubation, vasoactive medications for > 1 h, or noninvasive positive pressure ventilation for > 1 h) within 72 h. Patients meeting any endpoint within 1 h of arrival were excluded.
Results:
Nine hundred and eighty-five patients were enrolled, of whom 84 (8.5%) met the primary outcome of deterioration. Initial lactate ≥ 4.0 mmol/L had a specificity of 97% (95% confidence interval [CI] 94-100%), but a sensitivity of 27% (95% CI 18-37%) for predicting deterioration, with positive and negative likelihood ratios of 10.7 (95% CI 6.3-18.3) and 0.8 (95% CI 0.7-0.9), respectively. A lower threshold of lactate (≥2.0 mmol/L) had a sensitivity of 67% (95% CI 55-76%) and specificity of 66% (95% CI 63-69%), with corresponding positive and negative likelihood ratios of 2.0 (95% CI 1.7-2.3) and 0.5 (95% CI 0.4-0.7).
Conclusions:
High ED lactate is predictive of subsequent deterioration from sepsis within 72 h, and may be useful in determining disposition, but low lactate is not effective in screening stable patients at risk of deterioration.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
05:26Postconditioning with Lactate-enriched Blood for Cardioprotection in ST-segment Elevation Myocardial Infarction
Published on: May 28, 2019
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Mortar Joint Deterioration in Masonry
The...
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Emerging Adulthood