Related Experiment Video
Updated: Feb 13, 2026

Development of automated imaging and analysis for zebrafish chemical screens.
Published on: June 24, 2010
Development of quantitative screen for 1550 chemicals with GC-MS
Alan J Bergmann1, Gary L Points1, Richard P Scott1
1Department of Environmental and Molecular Toxicology, Oregon State University, 1007 Agricultural and Life Sciences Bldg., Corvallis, OR, 97331, USA.
Abstract:
With hundreds of thousands of chemicals in the environment, effective monitoring requires high-throughput analytical techniques. This paper presents a quantitative screening method for 1550 chemicals based on statistical modeling of responses with identification and integration performed using deconvolution reporting software. The method was evaluated with representative environmental samples. We tested biological extracts, low-density polyethylene, and silicone passive sampling devices spiked with known concentrations of 196 representative chemicals. A multiple linear regression (R2 = 0.80) was developed with molecular weight, logP, polar surface area, and fractional ion abundance to predict chemical responses within a factor of 2.5. Linearity beyond the calibration had R2 > 0.97 for three orders of magnitude. Median limits of quantitation were estimated to be 201 pg/μL (1.9× standard deviation). The number of detected chemicals and the accuracy of quantitation were similar for environmental samples and standard solutions. To our knowledge, this is the most precise method for the largest number of semi-volatile organic chemicals lacking authentic standards. Accessible instrumentation and software make this method cost effective in quantifying a large, customizable list of chemicals. When paired with silicone wristband passive samplers, this quantitative screen will be very useful for epidemiology where binning of concentrations is common. Graphical abstract A multiple linear regression of chemical responses measured with GC-MS allowed quantitation of 1550 chemicals in samples such as silicone wristbands.
Related Concept Videos
Chemical Formulas
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Chemical Equations
Chemical Reactions
Chemical Reactions Rearrange Atoms into New Substances
A chemical reaction takes starting materials—the reactants—and changes them...
Types of Chemical Bonds
Physical and Chemical Properties of Matter

