Related Experiment Video
Updated: Feb 13, 2026

Mouse Models for Graft Arteriosclerosis
Published on: May 14, 2013
Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition
Jacqueline J Blank1, Abby E Rothstein2, Cheong Jun Lee2
11 Division of Colorectal Surgery, Department of Surgery, Medical College of Wisconsin, Milwaukee, WI, USA.
Abstract:
Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon.
Case Report:
Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum.
Conclusions:
Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.
Insights
Iatrogenic misplacement of aortobifemoral bypass grafts through the colon is rare. This complication can lead to graft infection, requiring explantation and extra-anatomic bypass for recovery.
Area of Science:
- Vascular Surgery
- Surgical Complications
Background:
- Aortic graft infections are rare but serious complications following aortic revascularization.
- Surgical contamination is a common cause of these infections.
- Iatrogenic misplacement of aortobifemoral grafts is exceedingly rare, with undefined treatment principles.
Observation:
- Two cases of aortobifemoral bypass graft malposition through the colon are presented.
- Case 1 involved a 54-year-old male with graft placement through the sigmoid colon, presenting with an occult infection 6 months post-surgery.
- Case 2 involved a 60-year-old male with graft placement through the cecum, presenting with acute symptoms including fever and bacteremia 10 weeks post-surgery.
Findings:
- Both patients had their aortobifemoral grafts iatrogenically misplaced through the colon during the initial surgery.
- Graft malposition was confirmed intraoperatively in both cases.
- Infection presentation varied, with Case 1 showing indolent symptoms and Case 2 presenting more acutely.
Implications:
- This report highlights the critical importance of precise graft placement during aortobifemoral bypass surgery.
- Early recognition and surgical intervention, including graft explantation and extra-anatomic bypass, are crucial for patient recovery.
- Further research is needed to establish clear guidelines for the evaluation and management of this rare complication.
Related Concept Videos
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Secondary Active Transport
Secondary Active Transport
Secondary Healthcare System
Primary and Secondary Growth in Roots and Shoots
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...