Related Experiment Video
Updated: Feb 13, 2026

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Serial Diaphragm Ultrasonography to Predict Successful Discontinuation of Mechanical Ventilation
Atul Palkar1, Paul Mayo2, Karan Singh2
1Pulmonary & Critical Care Medicine, W. W. Backus Hospital, 330 Washington St # 430, Norwich, CT, 06360, USA. atulpalkar@gmail.com.
Introduction:
Diaphragm excursion and contraction velocity measured using ultrasonography have been used to assess diaphragm function. We aimed to evaluate the performance of diaphragm ultrasonography during weaning from mechanical ventilation (MV).
Methods:
Diaphragm ultrasonography was performed on 73 mechanically ventilated patients who were being considered for extubation on three separate occasions: (1) on assist control mode (A/C) during consistent patient triggered ventilation, (2) following 30 min during a spontaneous breathing trial (SBT), (3) 4-24 h following extubation. Right hemidiaphragm excursion and contraction velocity were measured on A/C, during SBT, and following extubation. These measurements were correlated with the outcome of extubation.
Results:
Twenty patients failed extubation: 6 of whom required re-intubation and 14 of whom required non-invasive ventilatory support. During SBT, the mean diaphragm excursions were 1.7 ± 0.82 cm in the group who failed extubation compared to 2.1 ± 0.9 cm in the group who were successfully extubated (p = 0.06). To predict successful extubation, a decrease in diaphragm excursion of < 16.4% between A/C and SBT had a sensitivity of 84.9% and a specificity of 65%. The area under curve (AUC) for receiver operative characteristics for above cut-off was 0.75. Diaphragm contraction velocity performed poorly in predicting weaning outcome.
Conclusions:
Diaphragm excursion measured during SBT is an imperfect predictor of the outcome of extubation. Maintenance of diaphragm excursion between A/C and SBT has good performance characteristics by AUC analysis. Diaphragm contraction velocity has poor ability to predict outcome of extubation.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Ecological Succession
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Limits with Oscillating Discontinuities