Related Experiment Video
Updated: Feb 13, 2026

Extraction of Plant-based Capsules for Microencapsulation Applications
Published on: November 9, 2016
Fabrication of a high selectivity magnetic solid phase extraction adsorbent based on β-cyclodextrin and application
Jiuyan Chen1, Shurui Cao2, Ming Zhu3
1College of Pharmacy, Chongqing Medical University, Chongqing, 400016, China.
Abstract:
An adsorbent, consisting of silica-coated Fe3O4 grafted graphene oxide and β-cyclodextrin (Fe3O4@SiO2/GO/β-CD), which possessed the merits of antioxidation, superparamagnetism, high surface area, high supramolecular recognition and environment friendly, was successfully fabricated. Considering the synergy between β-CD and graphene oxide in adsorption mechanism, the synthesized adsorbent could grasp compounds especially with aromatic structures through π-π interaction, hydrophobic interaction and host-guest inclusion complex forming. Based on the advantages, a magnetic solid phase extraction (MSPE) method for 9 PGRs using Fe3O4@SiO2/GO/β-CD as adsorbents was developed in this study. The characterizations of Fe3O4@SiO2/GO/β-CD were performed on Fourier transform infrared spectrometry (FT-IR), X-ray photoelectron spectroscopy (XPS), CHNS/O elemental analyzer, scanning electron microscopy (SEM) and vibrating sample magnetometry (VSM). Under the optimal MSPE condition, the Fe3O4@SiO2/GO/β-CD exhibited selectivity capability toward 9 PGRs when compared with Fe3O4@SiO2/GO. Meanwhile, the selectivity capability of Fe3O4@SiO2/GO/β-CD was higher than that of Fe3O4@SiO2/GO/α-CD except for 4-FPA. When the developed MSPE procedure was coupled with ultra-high performance liquid chromatography-triple quadrupole linear ion trap mass spectrometry (UHPLC-QTrap-MS/MS) to quantitative analysis of 9 PGRs, linearities ranging from 2 to 50 μg/kg were achieved for 9 PGRs with the correlation coefficients (r2) in the range of 0.9975-0.9999. The limits of detection (LODs) for 9 analytes varied from 0.04 to 0.29 μg/kg. Finally, the proposed technique was applied to analyze PGRs residues in mutiple vegetable samples.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
Meristems and Plant Growth
Plant Tissue Culture
Phase Diagrams
Key Elements for Plant Nutrition
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Structures of Solids