Related Experiment Video
Updated: Feb 12, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Coronary computed tomography angiography and endocardial leads - Image quality in 320-row CT using iterative
Marietta Garmer1, Marc Bonsels2, Frauke Metz2
1Witten/Herdecke University, Grönemeyer Institute for Microtherapy, Germany; Witten/Herdecke University, Clinical Radiology Wuppertal, Germany.
Purpose:
To investigate whether the presence of endocardial leads has an impact on image quality in coronary computed tomography angiography (CCTA), when current technique is employed using a 320-row computed tomography and iterative reconstruction.
Materials And Methods:
CCTA was performed in 1641 patients, from these we identified 51 patients (study group) with endocardial leads and 51 matched partners (control group) without endocardial leads. Noise was determined in the ascending aorta and the left ventricle; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined in the left and right coronary artery. Subjective image quality was rated separately for the 15 segments of the coronary arteries by 2 radiologists.
Results:
Current CCTA technique still shows slight impairment of objective image quality in patients with endocardial leads with inferior SNR in the aorta (median 15.04 versus 16.6; p = 0.004) and inferior SNR in the left/right coronary artery (median 15.3/13.81 versus 16.1/15.41; p = 0.013/0.002). CNR of the left/right coronary artery was also inferior (median 17.4/16.46 versus 19.26/19.24; p = 0.002/<0.001). The subjective image quality was rated significantly inferior only in segment 8 (p = 0.001) compared to the control group. Artifacts by ventricular leads were found in 65% of the patients in segment 8 with non-diagnostic rating in 9 cases (18%). Atrial leads resulted in artifacts predominantly in segment 1 (45%) with non-diagnostic rating in only 2 cases (4%).
Conclusion:
CCTA is feasible with slight restrictions for patients in the presence of implanted cardiac devices when current technique is used.
More Related Videos
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
09:11Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography Micro-CT Imaging Method
Published on: October 27, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT