Related Experiment Video
Updated: Feb 12, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Quinine-modified polymer monolithic column with reversed-phase /strong anion-exchange mixed-mode for pressurized
Jiabin Wang1,2, Changying Ding1, Jianhua Xiao2
1Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, P. R. China.
Abstract:
Via the facile ring-opening reaction of epoxy groups with quinine, a novel polymer monolith with quaternary ammonium for reversed-phase/strong anion-exchange mixed-mode has been fabricated for pressurized capillary electrochromatography (pCEC). Optimization on the preparation of quinine-modified monoliths has been investigated, and characteristics including morphology, permeability, mechanical stability, reproducibility, and column performance have been also studied. Active quaternary ammonium groups were conveniently produced to generate cationic action sites and stable anodic electroosmotic flow. Multiple interactions including reversed-phase, strong anion-exchange, electrostatic repulsion and π-π stacking interactions were obtained. Satisfactory separation capability of various analytes such as alkylbenzenes, polycyclic aromatic hydrocarbons, benzoic acid and its homologs, and β2 -receptor excitants has been achieved. Applied to the real sample, the good resolution of three alkaloids in Corydalis yanhusuo were achieved by pCEC with the quinine-modified monolith. The results light a potential access to facilely fabricating quaternary ammonium-functionalized polymer monolith with multiple interactions for efficient electrochromatography profiling of various compounds.
Related Concept Videos
Capillary Exchange
Types of Chemical Reactions: Exchange and Reversible
A special kind of exchange reaction is the oxidation-reduction reaction, or the redox reaction. These reactions involve the transfer of electrons from one compound to another. The electrons in these reactions commonly come from hydrogen atoms, which consist of an electron and a proton. A molecule gives up a...
Gas Exchange and Transport
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Polymers

