Estimating B1+ in the breast at 7 T using a generic template
Michael J van Rijssel1, Josien P W Pluim1, Peter R Luijten1
1Center for Image Sciences, UMC Utrecht, Utrecht, The Netherlands.
Abstract:
Dynamic contrast-enhanced MRI is the workhorse of breast MRI, where the diagnosis of lesions is largely based on the enhancement curve shape. However, this curve shape is biased by RF transmit (B1+ ) field inhomogeneities. B1+ field information is required in order to correct these. The use of a generic, coil-specific B1+ template is proposed and tested. Finite-difference time-domain simulations for B1+ were performed for healthy female volunteers with a wide range of breast anatomies. A generic B1+ template was constructed by averaging simulations based on four volunteers. Three-dimensional B1+ maps were acquired in 15 other volunteers. Root mean square error (RMSE) metrics were calculated between individual simulations and the template, and between individual measurements and the template. The agreement between the proposed template approach and a B1+ mapping method was compared against the agreement between acquisition and reacquisition using the same mapping protocol. RMSE values (% of nominal flip angle) comparing individual simulations with the template were in the range 2.00-4.01%, with mean 2.68%. RMSE values comparing individual measurements with the template were in the range8.1-16%, with mean 11.7%. The agreement between the proposed template approach and a B1+ mapping method was only slightly worse than the agreement between two consecutive acquisitions using the same mapping protocol in one volunteer: the range of agreement increased from ±16% of the nominal angle for repeated measurement to ±22% for the B1+ template. With local RF transmit coils, intersubject differences in B1+ fields of the breast are comparable to the accuracy of B1+ mapping methods, even at 7 T. Consequently, a single generic B1+ template suits subjects over a wide range of breast anatomies, eliminating the need for a time-consuming B1+ mapping protocol.
More Related Videos
Related Concept Videos
DNA as a Genetic Template
DNA as a Genetic Template
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Estimation of k and VD of Aminoglycosides
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Estimation of the Physical Quantities