Adaptively Optimized Combination of Phased-Array MR Spectroscopy Data Without Noise Correlation Estimation: A Joint
Liang Fang1,2, Minjie Wu1, Howard J Aizenstein1
1Department of Psychiatry, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
Abstract:
The adaptively optimized combination (AOC) method optimally combines multichannel magnetic resonance spectroscopy (MRS) data by incorporating noise correlations among receive coil elements/channels. These correlations are typically estimated from noise samples extracted from the fully decayed tails of acquired free induction decays (FIDs). To eliminate the need for FID noise tails and the corresponding interchannel noise correlation estimation, we propose a novel coil-combination method, termed AOC-JD, that exploits the intrinsic multichannel noise information contained in the differences between individual repetitions and the repetition-averaged spectroscopic data. The proposed method is based on joint diagonalization (JD) of two correlation matrices constructed from the individual repetitions and the repetition-averaged multichannel MRS data, thereby circumventing the conventional interchannel noise correlation estimation procedure. The performance of AOC-JD was evaluated using both computer simulations and in vivo human brain experiments. The results demonstrate that, when multichannel FIDs do not contain valid or sufficiently long noise tails, AOC-JD significantly improves the signal-to-noise ratio (SNR) of the combined spectra compared with the conventional singular value decomposition (SVD) method. Moreover, its performance is comparable to that of the original AOC method, which is optimized to maximize the SNR of the combined spectrum, when applicable. These findings demonstrate that AOC-JD provides a theoretically grounded and reliable approach for combining multichannel MRS data when FID noise tails are unavailable or insufficient.
Related Concept Videos
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
2D NMR: Overview of Heteronuclear Correlation Techniques
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...