An analysis of effective dose optimization and its impact on image quality and diagnostic efficacy relating to dental

Margarete B McGuigan1, Henry F Duncan1, Keith Horner2

  • 1Division of Restorative Dentistry & Periodontology, Dublin Dental University Hospital, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland

Swiss Dental Journal
|March 29, 2018
PubMed

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
406
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.9K
Impact Loading on a Cantilever Beam01:13

Impact Loading on a Cantilever Beam

The analysis of a cantilever beam with a circular cross-section subjected to impact loading at its free end illustrates the conversion of potential energy from a dropped object into kinetic energy, which is then absorbed by the beam as strain energy. This process is crucial for understanding how materials behave under dynamic loads, which is important in fields such as construction and aerospace.
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
905
Dose-Response Relationship: Potency and Efficacy01:22

Dose-Response Relationship: Potency and Efficacy

The potency of a drug is the measure of its ability to produce a biological response and can be compared by looking at the half-maximum effective concentration or EC50 values of different drugs. A lower EC50 value indicates higher potency of the drug. In the dose–response curve of two antihypertensive drugs, candesartan and irbesartan, a significant difference is observed in their EC50 values. A lower EC50 value for candesartan indicates that it is more potent than irbesartan, as it...
6.6K
Insulin: Dosing Regimen and Adverse Effects01:16

Insulin: Dosing Regimen and Adverse Effects

Insulin-replacement therapy usually includes both long-acting insulin (basal) and short-acting insulin (to cater to postprandial needs). In a diverse group of type 1 diabetes patients, the average daily insulin dose is typically 0.5-0.7 units/kg body weight. However, obese patients and pubertal adolescents may need more due to insulin resistance.
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
835
Relative Motion Analysis - Velocity01:24

Relative Motion Analysis - Velocity

A stroke engine has a slider-crank mechanism that converts rotational motion from the crank into linear motion of the slider or vice versa. This mechanism consists of three main parts: the crank, the connecting rod, and the slider.
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
759