Contrast-enhanced cone-beam breast-CT (CBBCT): clinical performance compared to mammography and MRI
Susanne Wienbeck1, Uwe Fischer2, Susanne Luftner-Nagel2
1Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Robert-Koch-Street 40, 37075, Göttingen, Germany. susanne.wienbeck@med.uni-goettingen.de.
Objectives:
To evaluate the diagnostic accuracy of contrast-enhanced (CE) cone-beam breast computed tomography (CBBCT) in dense breast tissue and compare it to non-contrast (NC) CBBCT, mammography (MG) and magnetic resonance imaging (MRI).
Methods:
This prospective institutional review board-approved study included 41 women (52 breasts) with American College of Radiology (ACR) density types c or d and Breast Imaging Reporting and Data System (BI-RADS) 4 or 5 assessments in MG or ultrasound (US). Imaging modalities were independently evaluated by two blinded readers.
Results:
A total of 100 lesions (51 malignant, 6 high-risk, and 43 benign) were identified. For readers 1/2, respectively, and p values comparing CE-CBBCT to other modalities: diagnostic accuracy (AUC) for CE-CBBCT was 0.83/0.77, for MRI 0.88/0.89 (p = 0.2272/0.002), for NC-CBBCT 0.73/0.66 (p = 0.038/ 0.0186) and for MG 0.69/0.64 (p = 0.081/0.0207). CE-CBBCT sensitivity (0.88/0.78) was 37-39% higher in comparison to MG (0.49/0.41, p < 0.001 both) but inferior to MRI (0.98/0.96, p = 0.0253/0.0027). CE-CBBCT specificity (0.71/0.71) was numerically higher compared to MRI (0.61/0.69, p = 0.0956/0.7389).
Conclusions:
CBBCT diagnostic performance varied with the respective reader and experience. CE-CBBCT improved AUC and sensitivity in comparison to MG and NC-CBBCT, and was comparable to MRI in dense breast tissue. In tendency, specificity was higher for CE-CBBCT than MRI.
Key Points:
• CE-CBBCT diagnostic accuracy (AUC) was comparable to MRI in dense breasts. • CE-CBBCT improved sensitivity and AUC in comparison to MG and NC-CBBCT. • CE-CBBCT has inferior sensitivity but higher specificity than MRI. • CE-CBBCT is a potential imaging alternative for patients with MRI contraindications.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...