Age-Related Susceptibility to Epileptogenesis and Neuronal Loss in Male Fischer Rats Exposed to Soman and Treated

Brenda Marrero-Rosado1, Franco Rossetti2, Matthew W Rice1

  • 1US Army Medical Research Institute of Chemical Defense, Aberdeen Proving Ground, Maryland 21010.

Related Concept Videos

Fischer Projections02:18

Fischer Projections

Learning to draw Fischer projections of molecules and understanding their relevance plays a crucial role in the visual depiction of organic molecules. A Fischer projection is a two-dimensional projection on a planar surface to simplify the three-dimensional wedge–dash representation of molecules. This is especially helpful in the case of molecules with multiple chiral centers that can be difficult to draw. Here, all the bonds of interest are represented as horizontal or vertical lines. While...
16.7K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
547
Infertility in Males01:23

Infertility in Males

Male infertility affects millions of couples worldwide, arising from various factors that impact different stages of the reproductive process. An endocrine imbalance resulting from conditions like hypogonadism, Klinefelter syndrome, or pituitary disorders can disrupt hormone levels and reduce sperm production. Testicular defects, such as tumors, cryptorchidism, atrophic testes, abnormal sperm morphology, and low sperm count or motility, may arise due to genetic factors, structural...
582
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
393
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.4K
Inhaled Medications01:23

Inhaled Medications

Inhaled medications are crucial for managing chronic obstructive pulmonary disease (COPD) and asthma. They are essential for effective treatment and control, ensuring optimal respiratory health and well-being. Inhaled medication delivers drugs directly to the lungs, providing a rapid onset of action and reducing systemic side effects compared to oral or injectable medications. Three primary types of inhalation devices are used to administer these medications: nebulizers, metered-dose inhalers...
829