Related Experiment Video
Updated: Feb 12, 2026

Preparation and Characterization of Individual and Multi-drug Loaded Physically Entrapped Polymeric Micelles
Published on: August 28, 2015
Evaluation of Bond Strength and Load Deflection Rate of Multi-stranded Fixed Retainer Wires: An In-Vitro Study
Renu Sarah Samson1, Eby Varghese2, Eswara Uma2
1Department of Orthodontics, Faculty of Dentistry, Melaka-Manipal Medical College, Melaka, Malaysia.
Background:
Fixed orthodontic retainers must be well retained on the tooth surfaces, allow physiologic movement of teeth and exert minimal forces on the teeth to be retained. Previous studies analyzed the bond strength and amount of deflection caused due to the debonding force but not the magnitude of force needed for unit deformation.
Aims:
This study aims to evaluate and compare the bond strength and load deflection rate (LDR) of three different fixed retainer wires.
Materials And Methods:
The wires were divided into three Groups: A - three-stranded twisted ligature wire, B - Bond-A-Braid (Reliance Orthodontics), and C - three-stranded twisted lingual retainer wire (3M Unitek). Twenty models were prepared for each group with a passive 15 mm long lingual retainer wire bonded to two lower incisors. An occlusogingival force was applied to the wire until it debonded. For LDR, three-point bending test was done at 0.5 mm deflection. These forces were measured using a Universal Instron Testing Machine.
Statistical Analysis:
Mean bond strength/LDR and pairwise comparisons were analyzed with one-way ANOVA and Tukey's honest significant difference post hoc test, respectively.
Results:
Group C exhibited the highest mean bond strength and LDR of 101.17N and 1.84N, respectively. The intergroup comparisons were all statistically significant.
Conclusion:
Compared to the other two wire types, Group C might be better retained on the teeth due to its higher bond strength. With its relatively higher LDR value, it may resist deformation from occlusal forces, thereby reducing inadvertent tooth movement and yet remain flexible enough to allow physiologic tooth movements.
Related Concept Videos
Fixing Double-strand Breaks
Fixing Double-strand Breaks
Bonding and Strength of Aggregate
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Bonding in Metals
Bond Energies and Bond Lengths

