New technologies improve adenoma detection rate, adenoma miss rate, and polyp detection rate: a systematic review and
Daniel Castaneda1, Violeta B Popov2, Elijah Verheyen1
1Department of Medicine, Mount Sinai St. Luke's-West Hospitals, Icahn School of Medicine, New York, New York, USA.
Background And Aims:
The need to increase the adenoma detection rate (ADR) for colorectal cancer screening has ushered in devices that mechanically or optically improve conventional colonoscopy. Recently, new technology devices (NTDs) have become available. We aimed to compare the ADR, polyp detection rate (PDR), and adenoma miss rate (AMR) between NTDs and conventional colonoscopy and between mechanical and optical NTDs.
Methods:
MEDLINE and Embase databases were searched from inception through September 2017 for articles or abstracts reporting ADR, PDR, and AMR with NTDs. Randomized controlled trials and case-control studies with >10 subjects were included. Primary outcomes included ADR, PDR, and AMR odds ratio (OR) between conventional colonoscopy and NTDs. Secondary outcomes included cecal intubation rates, adverse events, cecal intubation time, and total colonoscopy time.
Results:
From 141 citations, 45 studies with 20,887 subjects were eligible for ≥1 analyses. Overall, the ORs for ADR (1.35; 95% confidence interval [CI] 1.24-1.47; P < .01) and PDR (1.51; 95% CI, 1.37-1.67; P < .01) were higher with NTDs. Higher ADR (OR, 1.52 vs 1.25; P = .035) and PDR (OR, 1.63 vs 1.10; P ≤ .01) were observed with mechanical NTDs. The overall AMR with NTDs was lower compared with conventional colonoscopy (OR, .19; 95% CI, .14-.26; P < .01). Mechanical NTDs had lower AMRs compared with optical NTDs (OR, .10 vs .33; P < .01). No differences in cecal intubation rates, cecal intubation time, or total colonoscopy time were found.
Conclusions:
Newer endoscopic technologies are an effective option to improve ADR and PDR and decrease AMR, particularly with mechanical NTDs. No differences in operability and safety were found.
Related Concept Videos
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Related Rates
Speciation Rates
Measuring Reaction Rates
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Concentration and Rate Law
For example, in a generic reaction aA + bB ⟶ products, where a and b are stoichiometric coefficients, the rate law can be written as: