Comparison of Axillary and Temporal Artery Thermometry in Preterm Neonates
Objective:
To compare the accuracy of infrared temporal artery thermometry with axillary thermometry in a cohort of preterm neonates between 28 and 36 weeks postmenstrual age.
Design:
Descriptive repeated measures design with randomization to temperature measurement order.
Setting:
Level III NICU in the Central/Southeastern United States.
Participants:
Sixty-eight neonates born between 28 weeks and 36 weeks postmenstrual age cared for in incubators or open cribs.
Methods:
Neonates were randomly assigned to temperature measurement order (axillary followed by temporal artery or temporal artery followed by axillary). Temperature pairs were taken once during the day shift and once during the night shift. Behavioral states were assessed before, during, and after temperature measurement.
Results:
Neonates were predominantly female (64.7%) with a mean age of 6.6 days and a mean gestational age of 32.7 weeks, and most were cared for in incubators (n = 55). Noninferiority was observed between the two temperature methods (Holm-Bonferroni criterion = .025, p < .001). There was no statistically significant difference in the behavioral states of the neonates between the two temperature methods. It took nurses significantly longer to use the axillary thermometer than to use the temporal artery thermometer (p < .001).
Conclusion:
Temporal artery temperature measurements were as accurate as axillary temperature measurements in low-birth-weight neonates in the NICU. Nurses spent less time measuring with the temporal artery method than with the axillary method.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits