Related Experiment Video
Updated: Feb 12, 2026

Semi-automated Optical Heartbeat Analysis of Small Hearts
Published on: September 16, 2009
Heartbeat counting is unrelated to heartbeat detection: A comparison of methods to quantify interoception
Christopher Ring1, Jasper Brener2
1School of Sport, Exercise & Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom.
Abstract:
Recent research has identified individual differences in interoceptive sensitivity as a key source of variation in action, cognition, and emotion. This research has relied heavily on a single method for assessing interoceptive sensitivity: the accuracy of counting heartbeats while at rest. The validity of this method was assessed here by comparing the heartbeat counting (HBC) performance of 48 individuals with their heartbeat detection (HBD) performance. The HBC task required participants to report the numbers of heartbeats counted during brief signaled periods and indexed cardioceptive accuracy by the difference between the numbers of reported and actual heartbeats. In the HBD task, participants indicated the temporal location of heartbeat sensations relative to the onset of ventricular contraction. On each trial, they judged whether heartbeat sensations were or were not simultaneous with brief tones presented at one of six fixed delays following R waves of the ECG. In this method, cardioceptive accuracy or precision was indexed by variability in the temporal locations, relative to the R wave, of tones judged to be simultaneous with heartbeat sensations. Although intratask correlations indicated that each method yielded reliable scores, intertask correlations showed that HBC scores were unrelated to HBD scores. These results, which indicate that heartbeat detection and heartbeat counting are distinct processes, raise important questions about the assessment of interoceptive sensitivity and the involvement of this attribute in the psychological processes that have been associated with it on the basis of their correlations with HBC performance.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Quantifying Work
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons

