Phase of beta-frequency tACS over primary motor cortex modulates corticospinal excitability

Lukas Schilberg1, Tahnée Engelen1, Sanne Ten Oever1

  • 1Department of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands; Maastricht Brain Imaging Center, Maastricht, The Netherlands.

Related Concept Videos

Motor and Sensory Areas of the Cortex01:14

Motor and Sensory Areas of the Cortex

The cerebral cortex, the brain's outermost layer, is pivotal in processing complex cognitive tasks, emotions, and various sensory inputs and executing voluntary motor activities. This intricate structure is divided into three primary functional areas: the motor areas, sensory areas, and association areas.
Motor Areas
The motor areas located in the frontal lobe are central to controlling voluntary movements. This region is further subdivided into the primary motor cortex and the premotor cortex....
7.7K
Somatosensory, Motor, and Association Cortex01:23

Somatosensory, Motor, and Association Cortex

The somatosensory cortex in the parietal lobes is crucial for interpreting sensory data such as touch, temperature, and proprioception. The somatosensory cortex, situated in the parietal lobes, plays a vital role in interpreting sensory information like touch, temperature, and proprioception—awareness of body position. This specialized brain region features an organized structure wherein neurons at the top primarily process sensations originating from the lower body. In contrast, those at...
2.8K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
479
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
423
Frequency-dependent Selection01:21

Frequency-dependent Selection

When the fitness of a trait is influenced by how common it is (i.e., its frequency) relative to different traits within a population, this is referred to as frequency-dependent selection. Frequency-dependent selection may occur between species or within a single species. This type of selection can either be positive—with more common phenotypes having higher fitness—or negative, with rarer phenotypes conferring increased fitness.
24.2K
Phase Diagrams02:39

Phase Diagrams

A phase diagram combines plots of pressure versus temperature for the liquid-gas, solid-liquid, and solid-gas phase-transition equilibria of a substance. These diagrams indicate the physical states that exist under specific conditions of pressure and temperature and also provide the pressure dependence of the phase-transition temperatures (melting points, sublimation points, boiling points). Regions or areas labeled solid, liquid, and gas represent single phases, while lines or curves represent...
50.4K