Tricuspid valve surgery: repair and replacement.
Ahmed El-Eshmawi1, Dimosthenis Pandis2, David H Adams2
1Department of Cardiovascular Surgery, Mount Sinai Medical Center, New York, NY, USA - Ahmed.El-eshmawi@mountsinai.org.
Tricuspid valve disease, often overlooked, is increasingly recognized as significant. Current guidelines recommend proactive surgical intervention, particularly tricuspid annuloplasty, for better patient outcomes.
Area of Science:
- Cardiology
- Cardiac Surgery
- Valvular Heart Disease
Background:
- Tricuspid valve disease historically received less attention than other cardiac valves.
- Functional tricuspid regurgitation, secondary to right ventricular issues, is most common.
- Increased use of right-sided devices raises risk of organic tricuspid disease.
Purpose of the Study:
- To review surgical options and strategies for common tricuspid valve diseases.
- To highlight evolving guidelines advocating for proactive surgical management.
- To discuss advancements in tricuspid valve repair and replacement.
Main Methods:
- Review of current American and European guidelines.
- Analysis of surgical techniques, including tricuspid annuloplasty.
- Discussion of technological advancements in tricuspid valve therapies.
Main Results:
- Tricuspid regurgitation is not benign and often benefits from intervention.
- Tricuspid annuloplasty is the preferred technique with superior long-term outcomes.
- Newer annuloplasty rings and transcatheter therapies are expanding treatment options.
Conclusions:
- Tricuspid disease requires an aggressive surgical approach.
- Surgical repair is the gold standard for functional tricuspid regurgitation.
- Replacement is reserved for advanced or organic tricuspid disease.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
07:34Layer Microdissection of Tricuspid Valve Leaflets for Biaxial Mechanical Characterization and Microstructural Quantification
Published on: February 10, 2022
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Overview of DNA Repair
Chemically...
Base Excision Repair
The first step of...
Nucleotide Excision Repair
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...