Profiling, quantification and classification of cocoa beans based on chemometric analysis of carbohydrates using
Roberto Megías-Pérez1, Sergio Grimbs1, Roy N D'Souza1
1Department of Life Sciences and Chemistry, Jacobs University Bremen, Campus Ring 1, 28759 Bremen, Germany.
Abstract:
Fifty-six cocoa bean samples from different origins and status of fermentation were analyzed by a validated hydrophilic interaction liquid chromatography-electrospray ionization-time of flight-mass spectrometry (HILIC-ESI-TOF-MS) method. The profile of the low molecular weight carbohydrate (LMWC) was analyzed by high resolution and tandem mass spectrometry, which allowed the identification of mono-, di-, tri- and tetrasaccharides, sugar alcohols and iminosugars. This study provides, for the first time in a large set of samples, a comprehensive absolute quantitative data set for the carbohydrates identified in cocoa beans (fructose, glucose, mannitol, myo-inositol, sucrose, melibiose, raffinose and stachyose). Differences in the content of carbohydrates were observed between unfermented (range of 0.9-4.9 g/g DM) and fermented (range 0.1-0.5 g/g DM) cocoa beans. The use of multivariate statistical tools allowed the identification of biomarkers suitable for cocoa bean classification according to the status of fermentation, procedure of fermentation employed and number of days of fermentation.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation