Cytology cell blocks are suitable for immunohistochemical testing for PD-L1 in lung cancer

H Wang1, J Agulnik2, G Kasymjanova2

  • 1Divisions of Pathology & Molecular genetics, OPTILAB-McGill University Health Center, Montreal, Canada; Department of Pathology, McGill University, Montreal, Canada; Department of Medicine & Lady Davis Institute, Jewish General Hospital, Montreal, Canada.

Abstract

Related Concept Videos

PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
662
Lung Capacity01:47

Lung Capacity

The air in the lungs is measured in volumes and capacities. Lung volume measures reflect the amount of air taken in, released, or left over after a lung function, like a single inhalation. Lung capacity measures are sums of two or more lung volume measures.
56.4K
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
408
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
394
Block Diagram Reduction01:22

Block Diagram Reduction

The process of deriving the transfer function of a control system often involves reducing its block diagram to a single block. This simplification can be achieved through a series of strategic operations, including relocating branch points and comparators. These operations preserve the overall function of the system while allowing for easier manipulation and combination of blocks.
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
574
Elements of Block Diagrams01:25

Elements of Block Diagrams

Block diagrams serve as a visual representation of the input-output relationships within a system. An illustrative example is a heating system, where the set temperature activates the furnace to warm the room to the desired level. Block diagrams are versatile, modeling linear systems through Laplace transform variables and nonlinear systems using time domain variables.
A block diagram typically includes essential elements such as comparators, blocks, and feedback loops. Each of these elements...
730