Lymphocyte subset expression and serum concentrations of PD-1/PD-L1 in sepsis - pilot study

Julie K Wilson1, Yuan Zhao2, Mervyn Singer3

  • 1Department of Intensive Care Medicine, Guy's and St Thomas' Hospitals NHS Foundation Trust, London, SE1 7EH, UK. julie.2.wilson@kcl.ac.uk.

Abstract

Related Concept Videos

PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
662
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
408
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
394
Expressing Solution Concentration02:48

Expressing Solution Concentration

A solute is a component of a solution that is typically present at a much lower concentration than the solvent. Solute concentrations are often described with qualitative terms such as dilute (of relatively low concentration) and concentrated (of relatively high concentration).
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
69.2K
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
496
Serum Studies: Renal Function Tests01:24

Serum Studies: Renal Function Tests

Renal function tests are crucial for assessing kidney health, monitoring disease progression, and evaluating the kidneys' efficiency in waste elimination, fluid balance, and electrolyte regulation. These tests offer critical insights into kidney function, even though routine measurements may appear normal until there is a significant decline in the glomerular filtration rate or GFR. Typically, signs of kidney impairment only become evident when the GFR falls to about 50% of its normal level.
457