Contrast-enhanced computed tomography (CECT) attenuation is associated with stiffness of intact knee cartilage
Reza Nickmanesh1,2, Rachel C Stewart3,4, Brian D Snyder3,4
1University of British Columbia, Department of Orthopaedics, Vancouver, BC, Canada.
Abstract:
Contrast-enhanced computed tomography (CECT) using charged contrast-agents enables quantification of cartilage glycosaminoglycan content. Since glycosaminoglycan content is a key determinant of cartilage compressive stiffness, CECT measurements have the potential to non-invasively assess cartilage stiffness. The objective of this study was to determine whether CECT attenuation, using a cationic contrast-agent (CA4+), correlates with the stiffness of intact cartilage. Six fresh femoral and six fresh tibial compartments with intact cartilage were obtained from patients undergoing total knee replacement surgery. The instantaneous stiffness was determined for 25-50 points on the surface of each compartment using an established indentation technique. The samples were then immersed in CA4+ solution for 48 h, scanned in a micro-CT scanner, and the average CECT attenuation at each indentation site was found for the superficial cartilage. A significant (p < 0.01) and positive correlation was observed between stiffness and CECT attenuation for sites from each individual cartilage surface, with correlation coefficients ranging from r = 0.37-0.57 and r = 0.48-0.69 (p < 0.01) for the tibia and femur, respectively. When data for each type of cartilage surface were pooled together, the correlation coefficients were r = 0.73 for femoral condyle data points and r = 0.49 for tibial plateau data points. CECT provided a map of cartilage stiffness across each surface, which allows regions of low stiffness to be identified. These findings support continued evaluation and development of quantitative imaging techniques to assess the functional properties of cartilage. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2641-2647, 2018.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Self-Evaluation: Self-Enhancement and Self-Verification