Acute torrential mitral regurgitation during transcatheter aortic valve replacement: a case report
Yoshiyuki Yamashita1, Hiromichi Sonoda2, Tomoki Ushijima2
1Department of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. yossan43433@yahoo.co.jp.
Background:
Transcatheter aortic valve replacement (TAVR) is a minimally invasive approach to aortic valve replacement. However, critical cardiovascular collapse can occur during the procedure for various reasons.
Case Presentation:
A 90-year-old man with severe aortic stenosis and left circumflex artery stenosis developed acute torrential mitral regurgitation (MR) during TAVR. The valve deployment process induced left ventricular dyssynchrony due to left bundle-branch block and myocardial ischemia in the left circumflex artery region with torrential MR. Transesophageal echocardiography clearly demonstrated the mechanisms of MR, which was successfully bailed out by left ventricular pacing and intra-aortic balloon pumping.
Conclusions:
MR can be seriously exaggerated by various and complicated mechanisms during TAVR and should be rapidly assessed and appropriately managed depending on its mechanisms.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Mitral Regurgitation I: Introduction
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse I: Introduction
Mitral Regurgitation III: Medical Management
Mitral Regurgitation IV: Nursing Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests