Related Experiment Video
Updated: Feb 11, 2026

Endotracheal Intubation in Mice via Direct Laryngoscopy Using an Otoscope
Published on: April 5, 2014
Protection afforded by respirators when performing endotracheal intubation using a direct laryngoscope, GlideScope®,
Hyunggoo Kang1,2, Yoonje Lee1,2, Sanghyun Lee1,3
1Department of Emergency Medicine, College of Medicine, Hanyang University, Seoul, South Korea.
Abstract:
Emergency physicians are at risk of infection during invasive procedures, and wearing a respirator can reduce this risk. The aim of this study was to determine whether the protection afforded by a respirator during intubation is affected by the type of airway device used. In this randomized crossover study, 26 emergency physicians underwent quantitative fit tests for a N95 respirator (cup-type or fold-type) before and during intubation with a direct laryngoscope, GlideScope®, or i-gel® airway device. The primary outcome was the fit factor value of the respirator and the secondary outcome was the level of acceptable protection provided (percentage of fit factor scores above 100). Compared with the GlideScope and i-gel device, the fit factor values and level of acceptable protection provided were lower when physicians wore the cup-type respirator while intubating using the direct laryngoscope (200 fit factor [152-200] and 200 fit factor [121.25-200] versus 166 fit factor [70-200], 100% and 100% versus 75%, respectively; all P < 0.001). There were no significant differences in the fit factor value or level of acceptable protection provided when the physicians wore the fold-type respirator while intubating using any of the three airway devices (all P > 0.05). The type of airway device used for endotracheal intubation may influence the protective performance of some types of respirators. Emergency physicians should consider the effects of airway device types on fit factor of N95 respirators, when they perform intubation at risk of infection.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Respiration
Energy production in the human body is primarily fueled by oxidation, a process where food molecules are burned by combining with oxygen to produce carbon dioxide and water. This vital metabolic process sustains life, and is supported intricately by the respiratory system.
Structure and Function of the Respiratory System:
The respiratory system is a complex network of structures that includes the nose, oropharynx, larynx, trachea,...
Respiration Pathways
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...