Related Experiment Video
Updated: Feb 11, 2026

Preparation of Keratin Hydrolysate from Chicken Feathers and Its Application in Cosmetics
Published on: November 27, 2017
A miniaturized monolith-MWCNTs-COOH multi-stir-rod microextractor device for trace parabens determination in cosmetic
Fonthip Makkliang1, Proespichaya Kanatharana1, Panote Thavarungkul2
1Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand.
Abstract:
A portable and simple microextractor device was constructed by aligning six miniaturized multi-stir-rod microextractors. Each microextractor was prepared from rod-like multiwalled carbon nanotubes functionalized with a carboxylic group (MWCNTs-COOH) in composite monoliths that were bundled together and connected to a small DC motor. Using six of these microextractors, the device could extract six samples at the same time. A scanning electron microscope (SEM) showed the MWCNTs-COOH well distributed throughout the highly porous structure of the monolith-MWCNTs-COOH-stir-rod. This miniaturized multi-stir-rod microextractor device was used for the extraction of four parabens, methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP). Under optimized conditions, good linearities were obtained in the concentration range of 1.0 ng mL-1 to 1.0 µg mL-1 for MP and EP and 2.0 ng mL-1 to 1.0 µg mL-1 for PP and BP. The limits of detection were low, 636.2 ± 7.6 pg mL-1 for MP, 675.5 ± 6.0 pg mL-1 for EP, 676.6 ± 8.6 pg mL-1 for PP and 803.4 ± 9.6 pg mL-1 for BP. The developed microextractor could be used up to 15 times (%RSDs from 1.5 to 5.2) and also provided good preparation reproducibility (%RSD from 1.3 to 5.8, n = 6). The % RSDs of intra-day (n = 6) and inter-day (n = 6) precisions were obtained from 1.10-7.79 and 1.96-7.55, respectively. This developed device coupled with high performance liquid chromatography-diode array detector (HPLC-DAD) was applied for the extraction and preconcentration of four parabens in personal care products and cosmetics. The recoveries were studied by spiking the standard solution of parabens in real samples. Good recoveries were obtained in the range of 89.0 ± 2.7 to 102.7 ± 1.8% for MP, 88.09 ± 6.4 to 102.5 ± 1.0% for EP, 83.4 ± 6.4 to 102.9 ± 1.5% for PP and 83.5 ± 3.6 to 102.3 ± 2.0% for BP. This developed device might be easily applied for the extraction and preconcentration of other trace organic compounds in sample matrices.
More Related Videos
Related Concept Videos
Interdisciplinary Care: The Health Care Team-I
Physicians
The physician's primary responsibility is to diagnose illness and direct the medical or surgical treatment of the condition. The authority to admit patients to a healthcare agency or institution and practice care within that setting is granted to physicians by the healthcare agency or institution...
Interdisciplinary Care: The Health Care Team-II
Physical Therapist
A physical therapist (PT) aims to restore function or prevent additional impairment in a patient following an injury or disease. Massage, heat, cold, water, sonar waves, exercises, and electrical stimulation are some treatments used by PTs to treat...
Personal Identity
Continuing Care
Standards of Care I
Ostomy Care
An ostomy is a surgical procedure that creates an artificial opening from the intestines to the outside of the body, allowing for the rerouting of effluent. This opening is known as a stoma. A stoma usually protrudes above the skin surface, appearing pink or red, moist, and round, and it lacks nerve sensations.
There are different types of ostomies, including colostomies, ileostomies, and urostomies:

