Related Experiment Video
Updated: Feb 11, 2026

Optimized Management of Endovascular Treatment for Acute Ischemic Stroke
Published on: January 18, 2018
Protecting the ischaemic penumbra as an adjunct to thrombectomy for acute stroke
1Department of Neurology, Hôpital Sainte-Anne, Université Paris 5, INSERM U894, Paris, France. jean-claude.baron@inserm.fr.
Abstract:
After ischaemic stroke, brain damage can be curtailed by rescuing the 'ischaemic penumbra' - that is, the severely hypoperfused, at-risk but not yet infarcted tissue. Current evidence-based treatments involve restoration of blood flow so as to salvage the penumbra before it evolves into irreversibly damaged tissue, termed the 'core'. Intravenous thrombolysis (IVT) can salvage the penumbra if given within 4.5 h after stroke onset; however, the early recanalization rate is only ~30%. Direct removal of the occluding clot by mechanical thrombectomy considerably improves outcomes over IVT alone, but despite early recanalization in > 80% of cases, ~50% of patients who receive this treatment do not enjoy functional independence, usually because the core is already too large at the time of recanalization. Novel therapies aiming to 'freeze' the penumbra - that is, prevent core growth until recanalization is complete - hold potential as adjuncts to mechanical thrombectomy. This Review focuses on nonpharmacological approaches that aim to restore the physiological balance between oxygen delivery to and oxygen demand of the penumbra. Particular emphasis is placed on normobaric oxygen therapy, hypothermia and sensory stimulation. Preclinical evidence and early pilot clinical trials are critically reviewed, and future directions, including clinical translation and trial design issues, are discussed.
Related Concept Videos
Heart Failure VI: Adjunct Therapies
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...

