Post-treatment positron emission tomography-computed tomography is highly predictive of outcome in Plasmablastic
Yassine Al Tabaa1, Emmanuelle Tchernonog2, Pierre Faurie3
1Department of Nuclear Medicine, CHU Montpellier, 80 Avenue Augustin Fliche, 34095, Montpellier, Cedex 05, France. yassine.altabaa@gmail.com.
Purpose:
Plasmablastic lymphoma (PBL) is a rare variant of diffuse large B cell lymphomas (DLBCL) clinically characterized by a poorer prognostic. Few clinical and imaging data are available and derived from pooled case reports and small series. The aim of the study was to evaluate the FDG avidity at baseline and the utility of 18-Fluorodeoxyglucose (FDG) positron-emission-tomography/computed-tomography (PET/CT) for staging and response assessment.
Methods:
Patients with newly diagnosed PBL seen at Lymphoma Study Association centers during the period 2005-2015 were included if they underwent a PET/CT at staging and at the end of treatment (eotPET) and had received an anthracycline-based first line therapy. EotPET scans were analyzed using the 5-point-scale visual analysis in accordance with Lugano criteria. Patients were classified in complete metabolic response (CMR) or no-CMR including partial metabolic response (PMR), stable disease (SD) and progression disease (PD). EotPET results were assessed for the ability to predict event free survival (EFS) and overall survival (OS).
Results:
Thirty-five PBL patients fulfilled the inclusion criteria. The median follow-up was 34 months (2.8-120 months). FDG avidity was found in all patients at diagnosis. Most patients (80%) achieved CMR, and 20% were no-CMR including 9% PMR, 6% SD, and 6% PD. A CMR after first line chemotherapy predicted higher EFS (p < 0.0001) and OS (p = 0.0006).
Conclusions:
This study confirmed the FDG avidity of PBL subtype and the usefulness of PET/CT scanning in restaging an aggressive lymphoma at the completion of chemotherapy. EotPET can predict outcomes following treatment in patients with PBL.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Predicting Reaction Outcomes
Emission Spectra