Related Experiment Video
Updated: Feb 11, 2026

Author Spotlight: Improved Localization and Monitoring of Coronary Flow Reserve Using Modified PLAX View in Mice
Published on: August 25, 2023
Myocardial flow reserve derived by dynamic perfusion single-photon emission computed tomography reflects the severity
Nobuo Iguchi1, Yuko Utanohara2, Yasuhiro Suzuki3
1Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan. niguchi@shi.heart.or.jp.
Abstract:
A novel single-photon emission computed tomography (SPECT) camera was developed to evaluate dynamic myocardial perfusion flow. However, it is unclear whether myocardial flow reserve (MFR) derived by dynamic perfusion SPECT using the novel SPECT camera (D-SPECT) reflects the severity of coronary atherosclerosis. In the present study, we therefore examined the relationship between MFR using D-SPECT and severity of coronary lesions. The study population comprised 40 patients who underwent both a myocardial dynamic perfusion SPECT study and invasive coronary angiography. The severity of coronary atherosclerosis was evaluated using the Gensini score. All patients underwent a rest/stress SPECT imaging protocol using Tc-99m-sestamibi, and dynamic acquisition was performed. Stress and rest flow was evaluated, and the global and regional MFR was calculated. Global MFR showed a significant negative correlation with Gensini score (r = - 0.345, p = 0.037). Multiple linear regression analysis showed that only global MFR was independently related to Gensini score (p = 0.018). Regional MFR was significantly lower in regions with 90% ≤ stenotic lesions compared with regions with < 90% stenotic lesions (p = 0.009). Global MFR derived by dynamic perfusion SPECT using D-SPECT reflects the severity of coronary atherosclerosis. Further, regional MFR is modulated by severe coronary artery stenotic lesions.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies III: Computed Tomography
Emission Spectra
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Atherosclerosis III: Management

