Related Experiment Video
Updated: Feb 11, 2026

Displacement Analysis of Myocardial Mechanical Deformation DIAMOND Reveals Segmental Heterogeneity of Cardiac Function in Embryonic Zebrafish
Published on: February 6, 2020
Prelabour myocardial deformation and cardiac output in fetuses that develop intrapartum compromise at term: a
Amal A Alsolai1,2, Larissa N Bligh3, Ristan M Greer2,4
1a College of Applied Medical Science , King Saud University , Riyadh , Kingdom of Saudi Arabia.
Objective: Redistribution of cardiac output is responsible for the "brain sparing" effect seen during periods of acute or chronic fetal stress. We investigated the relationship between prelabour cardiac function in fetuses that subsequently developed intrapartum fetal compromise (IFC). Methods: A blinded, prospective, observational, cohort study, at Mater Mother's Hospital, Brisbane, Australia. A cohort of 284 women with uncomplicated singleton pregnancies underwent ultrasound every 2 weeks from 36 weeks until delivery. Fetal cardiac output was assessed by conventional Doppler ultrasound and myocardial deformation was measured using velocity vector imaging. Results: Two hundred and seventy three women were included in the final analysis, of which 19% had an emergency operative delivery for intrapartum fetal compromise (IFC). Global left ventricular strain (-12.1%, interquartile ranges (IQR) - 10.3 to -14% versus 13%, IQR -11.3 to -14.2%, p = .01) and strain rate (-1.00, IQR 0.85-1.16 s-1 versus -1.11, IQR -1.00 to -1.21 s-1, p < .001) were lower in fetuses that required any emergency operative delivery for IFC compared to those that did not. Global longitudinal right ventricular strain rate was lower in fetuses that developed IFC (-1.04 ± 0.22 s-1 versus 1.13 ± 0.22 s-1, p < .001), whereas global right ventricular strain did not show any significance differences between the two groups. Additionally, left ventricular cardiac output was lower in fetuses that developed IFC or had a composite neonatal morbidity (560 ± 44 mL/min versus 617 ± 72 mL/min, p < .001) or (581 ± 44 mL/min versus 612 ± 72 mL/min, p < .01), respectively. Conclusion: Lower global left ventricular strain and strain rate and cardiac output are associated with IFC and poorer condition of the newborn. Assessment of fetal cardiac function may be useful for risk stratification for intrapartum fetal compromise in apparently "low risk" term pregnancies.
Objective: Redistribution of cardiac output is responsible for the "brain sparing" effect seen during periods of acute or chronic fetal stress. We investigated the relationship between prelabour cardiac function in fetuses that subsequently developed intrapartum fetal compromise (IFC). Methods: A blinded, prospective, observational, cohort study, at Mater Mother's Hospital, Brisbane, Australia. A cohort of 284 women with uncomplicated singleton pregnancies underwent ultrasound every 2 weeks from 36 weeks until delivery. Fetal cardiac output was assessed by conventional Doppler ultrasound and myocardial deformation was measured using velocity vector imaging. Results: Two hundred and seventy three women were included in the final analysis, of which 19% had an emergency operative delivery for intrapartum fetal compromise (IFC). Global left ventricular strain (-12.1%, interquartile ranges (IQR) - 10.3 to -14% versus 13%, IQR -11.3 to -14.2%, p = .01) and strain rate (-1.00, IQR 0.85-1.16 s-1 versus -1.11, IQR -1.00 to -1.21 s-1, p < .001) were lower in fetuses that required any emergency operative delivery for IFC compared to those that did not. Global longitudinal right ventricular strain rate was lower in fetuses that developed IFC (-1.04 ± 0.22 s-1 versus 1.13 ± 0.22 s-1, p < .001), whereas global right ventricular strain did not show any significance differences between the two groups. Additionally, left ventricular cardiac output was lower in fetuses that developed IFC or had a composite neonatal morbidity (560 ± 44 mL/min versus 617 ± 72 mL/min, p < .001) or (581 ± 44 mL/min versus 612 ± 72 mL/min, p < .01), respectively. Conclusion: Lower global left ventricular strain and strain rate and cardiac output are associated with IFC and poorer condition of the newborn. Assessment of fetal cardiac function may be useful for risk stratification for intrapartum fetal compromise in apparently "low risk" term pregnancies.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Development of the Sexual Organs in the Embryo and Fetus
Near the gonadal ridges, two duct systems are present: the mesonephric ducts (Wolffian ducts) and paramesonephric ducts (Müllerian ducts). These ducts form the basis for the...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...

