Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Groin Haemostasis With a Purse String Suture for Patients Following Catheter Ablation Procedures (GITAR Study)
Nicholas Jackson1, Michael McGee1, Waheed Ahmed1
1John Hunter Hospital, New Lambton, NSW, Australia; The University of Newcastle, Newcastle, NSW, Australia.
Background:
The most frequent complications from percutaneous electrophysiology procedures relate to vascular access. We sought to perform the first randomised controlled trial for femoral venous haemostasis utilising a simple and novel purse string suture (PSS) technique.
Methods:
We randomised 200 consecutive patients who were referred for electrophysiology procedures at two different hospitals to either 10minutes of manual pressure or a PSS over the femoral vein and determined the incidence of vascular access site complications.
Results:
The mean age was 61.8±12.1years and 138 (69%) were male. Bleeding requiring addition pressure or a FemStop (Abbott Laboratories, Abbott Park, IL, USA) for complete haemostasis occurred in 17/99 (17%) patients in the PSS arm and 19/101 (19%) patients in the manual pressure arm (p=0.72). There were no cases of haematoma prolonging hospital stay, arterio-venous fistula, pseudoaneurysm or retroperitoneal bleeding. The mean duration to achieve haemostasis was 45seconds in the PSS arm and 10minutes 44seconds in the manual pressure arm (p<0.001). Pain/discomfort associated with haemostasis occurred in 15/99 (15%) patients in the PSS arm and in 29/101 (29%) patients receiving manual pressure (p=0.03).
Conclusions:
In this randomised trial we demonstrate that an easy to perform PSS is as effective at achieving haemostasis as 10minutes of manual pressure for catheter ablation procedures. The PSS is considerably faster to perform and is more comfortable for patients than manual pressure.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Related Concept Videos
Problem-Solving: Tuning of a Guitar String
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Bioavailability Study Design: Healthy Subjects Versus Patients
Blind Procedures
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Handwashing III: During the Procedure and Post-Procedure Steps