Related Experiment Video
Updated: Feb 11, 2026

06:13
The Intra-Aortic Balloon Pump
Published on: February 5, 2021
24.9K
Impella: pumps overview and access site management
Francesco Burzotta1, Giulio Russo2, Leonardo Previ2
1Institute of Cardiology, Catholic University of the Sacred Heart, A. Gemelli University Hospital, Rome, Italy - francesco.burzotta@unicatt.it.
Minerva Cardioangiologica
|April 25, 2018
Summary
The Impella ventricular support system offers various catheters for heart assistance. Proper access site management is crucial to minimize vascular complications during Impella device use.
Area of Science:
- Cardiovascular Engineering
- Medical Devices
- Interventional Cardiology
Background:
- The Impella system is a leading ventricular support device.
- It comprises microaxial pump catheters and an external controller.
- Four catheter types exist: Impella 2.5, CP, 5.0, and LD, differing in size and flow capacity.
Purpose of the Study:
- To detail the components and variations of the Impella left ventricular support system.
- To outline the insertion methods and common applications for different Impella models.
- To emphasize the importance of access site management for minimizing complications.
Main Methods:
- Description of Impella catheter types (2.5, CP, 5.0, LD) and their specifications.
- Explanation of percutaneous (femoral) and surgical (axillary, aorta) insertion approaches.
- Highlighting patient selection criteria for specific Impella devices, particularly for cardiogenic shock.
Main Results:
- Impella 2.5 and CP (12F/14F) are for percutaneous insertion (up to 2.5/4.1 L/min).
- Impella 5.0 and LD (21F) are for surgical insertion.
- Femoral access is common for percutaneous insertion, while axillary is an alternative for surgical insertion.
- Impella CP and 5.0 are frequently used in cardiogenic shock.
Conclusions:
- The Impella system provides diverse options for left ventricular support.
- Access site selection (femoral vs. axillary) depends on patient anatomy and support duration.
- Vigilant access site management is essential to prevent vascular complications with Impella use.
Related Concept Videos
ATP Driven Pumps I: An Overview
9.9K
ATP-driven pumps, also known as transport ATPases, are integral membrane proteins. They have binding sites for ATP located on the membrane's cytosolic side and the ion-conducting domain in the transmembrane region. These pumps use the free energy released from ATP hydrolysis to move the solutes across cell membranes against an electrochemical gradient.
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
9.9K
ATP Driven Pumps III: V-type Pumps
4.9K
V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
4.9K
ATP Driven Pumps II: P-type Pumps
6.5K
The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
6.5K
Pumped Concrete
401
Concrete in large quantities can be pumped across long distances for placing in inaccessible sites. This system comprises a hopper that receives concrete from a mixer, a pump to propel the concrete, and pipelines that facilitate its delivery.
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
401
Refrigerators and Heat Pumps
3.1K
Refrigerators or heat pumps are heat engines operating in a reverse direction. For a refrigerator, the focus is on removing heat from a specific area, whereas, for a heat pump, the focus is on dumping heat into one particular area. A refrigerator (or heat pump) absorbs heat Qc from the cold reservoir at Kelvin temperature Tc and discards heat Qh to the hot reservoir at Kelvin temperature Th, while work W is done on the engine’s working substance.
A household refrigerator removes heat from...
A household refrigerator removes heat from...
3.1K
Tonsillitis II: Management
445
This lesson will focus on the different treatment options for managing tonsillitis, which typically depend on the cause and severity.
445