Related Experiment Video
Updated: Feb 11, 2026

The Intra-Aortic Balloon Pump
Published on: February 5, 2021
Impella: pumps overview and access site management
Francesco Burzotta1, Giulio Russo2, Leonardo Previ2
1Institute of Cardiology, Catholic University of the Sacred Heart, A. Gemelli University Hospital, Rome, Italy - francesco.burzotta@unicatt.it.
Abstract:
The Impella left ventricular support system consists of two main components: a family of different ventricular support catheters with a microaxial pump to be placed across the aortic valve and a single external controller which is connected to activate and control the pump function. Four Impella left ventricular support catheters are available: Impella 2.5, Impella CP, Impella 5.0 and Impella LD. Impella 2.5 and Impella CP are designed for percutaneous peripheral insertion, have respectively a 12F and 14F maximal diameter at the pump level and are capable of providing up to 2.5 and 4.1 liters per minute, respectively. Impella 5.0 and Impella LD have 21F maximal diameter at the pump level and are designed for surgical insertion through, respectively, a peripheral artery (femoral or axillary) or the aorta. The Impella CP or 5.0 are commonly selected for cardiogenic shock patients. The femoral approach represents the most adopted access site for percutaneous Impella insertion. Yet, it requires the presence of suitable aorto-iliac-femoral arterial axis for retrograde advancement of the Impella pump. The axillary artery is usually the main alternative approach for surgical insertion in the patients with unfavorable peripheral anatomy or for patients requiring prolonged assistance. When adopting Impella pumps, maximal attention should be paid to the access site management before, during and after cardiac assistance in order to minimize the risk of vascular complications.
Related Concept Videos
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Tonsillitis II: Management

