Related Experiment Video
Updated: Feb 11, 2026

Using Multiple Light Scattering to Examine the Stability of Phyllanthus emblica L. Extracts Obtained with Different Extraction Methods
Published on: April 14, 2023
Extractability-mediated stability bias and hematocrit impact: High extraction recovery is critical to feasibility of
Iris Xie1, Yang Xu1, Melanie Anderson1
1Merck Co. & Inc., Pharmacokinetics, Pharmacodynamics and Drug Metabolism, Regulated Bioanalysis, 770 Sumneytown Pike, WP75B-300, West Point, PA 19486, USA.
Abstract:
Volumetric absorptive microsampling (VAMS), a new microsampling technique, was evaluated for its potential in supporting regulated bioanalysis. Our initial assessment with MK-0518 (raltegravir) using a direct extraction method resulted in 45-52% extraction recovery, significant hematocrit (Ht) related bias, and more importantly, unacceptable stability (>15% bias from nominal concentration) after 7-day storage. Our investigation suggested that the observed biases were not due to VAMS absorption, sampling techniques, lot-to-lot variability, matrix effect, and/or chemical stability of the compound, but rather the low extraction recovery. An effort to improve assay recovery led to a modified liquid-liquid extraction (LLE) method that demonstrated more consistent performance, minimal Ht impact (Ht ranged from 20 to 65%), and acceptable sample stability. The same strategy was successfully applied to another more hydrophilic model compound, MK-0431 (sitagliptin). These results suggest that the previously observed Ht effect and "instability" were in fact due to inconsistent extractability, and optimizing the extraction recovery to greater than 80% was critical to ensure VAMS performance. We recommend adding Ht-independent recovery as part of feasibility assessment to de-risk the long-term extractability-mediated stability bias before implementing VAMS in regulated bioanalysis.
More Related Videos
10:21Microsampling in Targeted Mass Spectrometry-Based Protein Analysis of Low-Abundance Proteins
Published on: January 13, 2023
08:27Design and Validation of a Volumetric-extrusion Bioprinter for Bioprinting of Soluble Basement Membrane Extract for Translational Research
Published on: March 28, 2025
Related Concept Videos
Extraction: Effects of pH
Hindsight Biases
Extraction: Advanced Methods
Confirmation Biases
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...
Bias
In statistics, a sampling bias is created when a sample is collected from a population, and some members of the population are not as likely to be chosen as others (remember, each member...