Chromatographic Resolution01:15

Chromatographic Resolution

2.2K
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
2.2K
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

250
A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
250
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

4.0K
Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
4.0K
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

4.0K
Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
4.0K
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

1.0K
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
1.0K
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

261
Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
261

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Extraction mechanisms of proteins from Palmaria palmata.

Food chemistry·2026
Same author

Comparing isotherm parameter determination methods for hydrophobic interaction chromatography.

Journal of chromatography. A·2026
Same author

A Review on Quantitative Process Analytical Technology for Continuous Downstream Processing of Monoclonal Antibodies.

Biotechnology and bioengineering·2025
Same author

Towards Rapid Calibration of Bioprocess Quantification Models Using Single Compound Raman Spectra: A Comparison of Four Approaches.

Biotechnology and bioengineering·2025
Same author

Impact of bioreactor process parameters and yeast biomass on Raman spectra.

Biotechnology progress·2025
Same author

Optimization of multi-column chromatography for capture and polishing at high protein load.

Biotechnology progress·2025
Same journal

Advanced glucose control strategies leveraging Raman spectroscopy for optimized mammalian cell culture manufacturing.

Biotechnology progress·2026
Same journal

Mechanistic deconvolution of BSA size variants by constrained Raman pseudo-Voigt hard modeling during anion-exchange chromatography.

Biotechnology progress·2026
Same journal

Status and future of recombinant adeno-associated virus vector manufacturing.

Biotechnology progress·2026
Same journal

Multifaceted algae as an ingredient in alternative meat formulations.

Biotechnology progress·2026
Same journal

In-line Raman spectroscopy real-time glucose prediction method for commercial pneumococcal vaccine drug substance fermentation manufacturing process control.

Biotechnology progress·2026
Same journal

Prolonged autophagy induction correlates with host cell protein reduction in CHO cell culture.

Biotechnology progress·2026
See all related articles

Related Experiment Video

Updated: Feb 11, 2026

Production of Chemicals by Klebsiella pneumoniae Using Bamboo Hydrolysate as Feedstock
07:24

Production of Chemicals by Klebsiella pneumoniae Using Bamboo Hydrolysate as Feedstock

Published on: June 29, 2017

9.5K

Chromatographic parameter determination for complex biological feedstocks.

Silvia M Pirrung1, Diogo Parruca da Cruz1, Alexander T Hanke1

  • 1Dept. of Biotechnology, Delft University of Technology, Van der Maasweg 9, Delft, 2629 HZ, the Netherlands.

Biotechnology Progress
|April 26, 2018
PubMed
Summary
This summary is machine-generated.

This study presents a robotic liquid handling system for determining chromatography model parameters from complex biological feedstocks, improving mechanistic model accuracy and efficiency for monoclonal antibody purification.

Keywords:
chromatographydownstream processing (DSP)high-throughput process development (HTPD)mechanistic modeling

More Related Videos

Multimer-PAGE: A Method for Capturing and Resolving Protein Complexes in Biological Samples
07:40

Multimer-PAGE: A Method for Capturing and Resolving Protein Complexes in Biological Samples

Published on: May 5, 2017

12.1K
Structure and Coordination Determination of Peptide-metal Complexes Using 1D and 2D 1H NMR
14:44

Structure and Coordination Determination of Peptide-metal Complexes Using 1D and 2D 1H NMR

Published on: December 16, 2013

10.1K

Related Experiment Videos

Last Updated: Feb 11, 2026

Production of Chemicals by Klebsiella pneumoniae Using Bamboo Hydrolysate as Feedstock
07:24

Production of Chemicals by Klebsiella pneumoniae Using Bamboo Hydrolysate as Feedstock

Published on: June 29, 2017

9.5K
Multimer-PAGE: A Method for Capturing and Resolving Protein Complexes in Biological Samples
07:40

Multimer-PAGE: A Method for Capturing and Resolving Protein Complexes in Biological Samples

Published on: May 5, 2017

12.1K
Structure and Coordination Determination of Peptide-metal Complexes Using 1D and 2D 1H NMR
14:44

Structure and Coordination Determination of Peptide-metal Complexes Using 1D and 2D 1H NMR

Published on: December 16, 2013

10.1K

Area of Science:

  • Biotechnology
  • Chemical Engineering
  • Chromatography

Background:

  • Accurate model parameters are crucial for mechanistic chromatography models.
  • Complex feedstocks and limited sample material hinder parameter determination.
  • Current methods face obstacles in efficiently characterizing complex biological samples.

Purpose of the Study:

  • To implement and validate an automated approach for determining chromatography model parameters.
  • To utilize a robotic liquid handling system for direct analysis of complex feedstocks.
  • To enable accurate predictions for large-scale chromatography using small-scale experimental data.

Main Methods:

  • Utilized a robotic liquid handling system with RoboColumns (200 μL bed volume).
  • Determined isotherm parameters directly from a complex feedstock containing a monoclonal antibody.
  • Validated the approach by comparing experimental data with model predictions.

Main Results:

  • Achieved excellent agreement between model predictions and independent experimental data.
  • Demonstrated the effectiveness of RoboColumns for parameter determination.
  • Verified the accuracy of the developed approach for complex biological feedstocks.

Conclusions:

  • The robotic liquid handling approach successfully determines crucial model input parameters.
  • RoboColumns are suitable for obtaining isotherm parameters for large-scale chromatography predictions.
  • This method enhances the application of mechanistic models for complex biopharmaceutical processes.