O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
ATR-IR coupled to partial least squares regression (PLSR) for monitoring an encapsulated active molecule in complex
Lynda Miloudi1, Franck Bonnier, Kevin Barreau
1Université François-Rabelais de Tours, EA 6295 Nanomédicaments et Nanosondes, 31 avenue Monge, 37200 Tours, France. franck.bonnier@univ-tours.fr.
Abstract:
Attenuated Total Reflectance-Infrared (ATR-IR) spectroscopy holds great promise for industrial applications as a quality control tool for complex galenic formulations. Although the technique is often promoted for the molecular information it delivers in a label free and cost effective fashion, other advantages can emerge compared to the gold standard analytical tools such as liquid chromatography coupled to mass spectrometry. The present study demonstrates how ATR-IR measurements enable accurate quantitative analysis of an active cosmetic ingredient such as Omegalight® encapsulated in a complex alginate based nano-capsule. The study demonstrates how precise concentrations can be obtained without the requirement for fastidious extraction and separation protocols prior to ATR-IR analysis. However, data mining remains a crucial aspect with particular emphasis on the preprocessing of the data that will be subjected to Partial Least Squares Regression (PLSR) analysis. Therefore, different pre-processing methods have been evaluated to investigate the relationship between corrections applied and PLSR outcomes (i.e. precision, ratio of performance to deviation (RPD) and accuracy of the analysis). Ultimately, it has been found that, against all expectations, some of the preprocessing methods do not necessarily lead to improvements in the end result, while Extended Multiplicative Scattering Correction (EMSC) is the only one which delivers satisfying results, as defined by a Root Mean Square Error (RMSEV) of 0.07% (w/w) and a RPD greater than 30 when performing analysis over the range 0.4-8.2% (w/w). Despite the presence of large amounts of additives such as glycerol and preservatives in the formulation, implementing Leave One Out Cross Validation (LOOCV) further validates the method with a RPD of 18 and relative errors for the predicted concentrations below the 5% (w/w) threshold, hence demonstrating that ATR-IR has analytical capabilities for applications in the cosmetic industry.
Related Concept Videos
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Couples: Scalar and Vector Formulation
A couple moment is a rotational force that tends to rotate the steering wheel. The wheel's rotation can either be in a clockwise or anticlockwise direction. The right-hand rule is a helpful method for determining the direction of a couple moment....
Regression Toward the Mean
Structures of Solids
Punnett Squares
Formation of Complex Ions