Comparison of volarly and dorsally displaced distal radius fracture treated by volar locking plate fixation
1Department for Trauma Surgery, Tirol Kliniken, Medical University Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria. stefanie.erhart@tirol-kliniken.at.
Introduction:
In case of distal radius fractures (DRF) the distal fragment generally displaces either dorsally or volarly. Scientific literature however, seldom differentiates between volarly and dorsally displaced DRFs when reporting results. It is no clear, if the direction of displacement has an influence on the clinical and radiological outcome. This study was intended to evaluate the influence of displacement direction in adult patients with surgically treated Colles or Smith type fractures.
Patients And Methods:
After a mean follow up (FU) time of above 5 years, 50 patients who underwent open reduction and internal fixation for DRFs (25 Smith type fractures, 25 Colles type fractures) were included. Upon FU, standard X-rays and a clinical evaluation as well as evaluation scores were raised and analysed.
Results:
Clinical evaluation showed no difference between the Colles and the Smith group. Radiologic and clinical results for the Colles group showed diminished flexion compared to the healthy wrist, decreased radial inclination and dorsal tilt during FU and progression of osteoarthritis. For the Smith group decreased grip strength compared to the healthy wrist and osteoarthritis-progression was found. For both groups there was no correlation between radiologic values, grip strength, arthrosis grading, disability of arm, shoulder and hand score and patient rated wrist evaluation score.
Discussion:
Decreased flexion in combination with a decreased dorsopalmar tilt might hint towards a mechanical inhibition in the Colles group. Altogether, the study showed good clinical outcome with satisfactory radiological result. As all patients showed arthrosis progression, the fracture per se is to be seen as a prearthrotic factor. It still remains unclear which measures could be taken to prevent this.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Related Concept Videos
Radius of Gyration of an Area
Displacement Current
Position and Displacement
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...