Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
2D shear wave elastography combined with MELD improved prognostic accuracy in patients with acute-on-chronic
Jie-Yang Jin1,2, Yu-Bao Zheng2,3, Jian Zheng1,2
1Department of Medical Ultrasonics, the Third Affiliated Hospital of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China.
Objectives:
To evaluate accuracy of two-dimensional shear wave elastography (2D SWE) and develop and validate a new prognostic score in predicting prognosis of acute-on-chronic liver failure (ACLF) patients.
Methods:
From 1 October 2013 to 30 September 2015, we consecutively enrolled 290 patients, sequentially collected data (including 2D SWE, ultrasound parameters, laboratory data and prognostic scores) and recorded patients' outcome (recovering/steady or worsening) during a 90-day follow-up period. We evaluated ability of 2D SWE to predict outcomes of acute-on-chronic hepatitis B liver failure (ACLF-HBV) patients. We developed a new score (MELD-SWE, combining MELD and SWE values) for predicting mortality risk of ACLF-HBV in 179 patients in a derivation group, and validated in 111 patients.
Results:
2D SWE values were higher in worsening patients than recovering/steady ones (p < 0.001). Accuracy of 2D SWE in predicting outcomes of ACLF-HBV was comparable to that of the MELD score (p = 0.441). MELD-SWE showed a significantly higher prognostic value than MELD in both derivation (AUROC, 0.80 vs. 0.76, p = 0.040) and validation (AUROC, 0.87 vs. 0.82, p = 0.018) group.
Conclusions:
The MELD-SWE score, combining MELD and SWE values, was superior to MELD alone for outcoming prediction in patients with ACLF-HBV.
Key Points:
• 2D SWE is a simple prognostic evaluation tool in patients with ACLF-HBV. • MELD-SWE was created in this study: 1.3×MELD + 0.3×2D SWE (kPa). • MELD-SWE score was superior to MELD alone for outcoming prediction in ACLF-HBV. • In this study, 46.8 was the optimal cut-off value of MELD-SWE score.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
07:10Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-III