Related Experiment Video
Updated: Feb 11, 2026

How to Obtain Reliable Visual Event-related Potentials in Newborns
Published on: October 24, 2019
Visual evoked potentials are similar in polysomnographically defined quiet and active sleep in healthy newborns
Lourdes Cubero-Rego1, María Corsi-Cabrera2, Josefina Ricardo-Garcell1
1Research Unit in Neurodevelopment, Institute of Neurobiology, National Autonomous University of Mexico, Querétaro, 76230, Mexico.
Insights
Visual Evoked Potentials (VEPs) in newborns are more reliable during active sleep (AS) than quiet sleep (QS). This study found no significant VEP differences between sleep stages, but AS yielded more consistent results for neonatal visual pathway development assessment.
Area of Science:
- Neonatal neurophysiology
- Developmental neuroscience
- Ophthalmology
Background:
- Visual Evoked Potentials (VEPs) assess visual pathway development in newborns.
- Previous studies show high variability in neonatal VEPs, with unclear effects of sleep stages.
- Adult VEPs are known to vary with wake-sleep stages.
Purpose of the Study:
- To characterize Visual Evoked Potentials (VEPs) in one-month-old healthy newborns.
- To compare VEPs during active sleep (AS) and quiet sleep (QS).
- To correlate VEP components with EEG frequency bands during different sleep states.
Main Methods:
- VEPs were recorded from 20 healthy, full-term newborns using monocular LED stimulation.
- Simultaneous polysomnography (PSG) defined active sleep (AS) and quiet sleep (QS).
- Latencies and amplitudes of N2, P2, and N3 VEP components were analyzed and compared between sleep states.
Main Results:
- No significant differences in VEP morphology, latency, or amplitude were found between AS and QS.
- Typical VEP waveforms were observed in all newborns during AS.
- VEPs were less reliable in QS, requiring more averaging and showing lower correlation between averages.
Conclusions:
- Adult-like sleep-stage-dependent VEP changes are not yet present in one-month-old neonates, likely due to immature cortical and sleep mechanisms.
- VEPs are more reliable in newborns during active sleep (AS) compared to quiet sleep (QS).
- Systematic VEP recording during AS, confirmed by PSG, is recommended to enhance the reliability of neonatal VEP assessments.
Abstract:
Morphology and late components of evoked potentials change depending on wake-sleep stages in adults. Visual Evoked potentials (VEPs) have been frequently studied in newborns to identify abnormal development of visual pathways; however, large variability has been reported and there is uncertainty as to the effect of sleep stages on VEPs in neonates.
Objective:
To describe the characteristics of VEPs in one month old, healthy full-term newborns during active sleep (AS) and quiet sleep (QS), defined by simultaneous polysomnography (PSG).
Methods:
VEPs were obtained by monocular LEDs stimulation of each eye during AS and QS, in 20 healthy full-term newborns (gestational age 37-40 weeks) with normal birth weights and normal prenatal Doppler ultrasound indices. Latencies and amplitudes of N2, P2 and N3 components in AS and QS were compared, and their association with absolute power of EEG frequency bands, assessed.
Results:
There were no significant differences in VEP morphology, latencies and amplitudes between sleep states. Typical wave forms were obtained in all newborns in AS; however, no VEPs could be identified clearly in 3 newborns in QS; QS VEPs were less reliable than in AS: more averaging was required; correlation was significantly lower between the VEP averages; and a larger number of babies needed more than two averages to obtain replicable responses needed for clinical purposes.
Conclusions:
These results indicate that changes in amplitude and latency of some VEP components observed in NREM and REM sleep in adults are not yet present in one month old newborns probably due to immaturity of cortical and sleep mechanisms. VEPs are more reliable during AS than QS in newborns. Systematic VEP recording during AS, and polysomnographic control to identify this stage, are highly recommended as methods that can increase there liability of neonatal VEPs.
Related Concept Videos
Thermodynamics: Chemical Potential and Activity
The thermodynamic equilibrium constant is more accurately defined in terms of activity rather than concentration.
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...
Understanding Sleep
The circadian rhythm, a nearly 24-hour cycle, is deeply influenced by environmental light cues. Light exposure directly affects the hypothalamus, which in turn regulates...
Sleep Apnea
The condition is more prevalent among...
Defining Psychology