Related Experiment Video
Updated: Feb 11, 2026

miRNA Expression Analyses in Prostate Cancer Clinical Tissues
Published on: September 8, 2015
Is Prostate Imaging Reporting and Data System Version 2 Sufficiently Discovering Clinically Significant Prostate
Myoung Seok Lee1, Min Hoan Moon1, Young A Kim2
11 Department of Radiology, Seoul Metropolitan Government, Seoul National University Boramae Medical Center, 20 Boramae-ro-5-Gil, Dongjak-Gu, Seoul 07061, Korea.
Objective:
The objective of our study was to evaluate the performance of multiparametric MRI with Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for detecting prostate cancer (PCA) and clinically significant PCA through this per-lesion one-to-one correlation study between pathologically proven lesions and MRI-visible lesions.
Materials And Methods:
A total of 93 PCA lesions from 44 patients who underwent radical prostatectomy were included in this retrospective study. Two radiologists scored every visible lesion with a PI-RADSv2 score of 3, 4, or 5 in each patient's multiparametric MRI examination using PI-RADSv2. A per-lesion one-to-one correlation between MRI-visible lesions and pathologically confirmed PCA lesions was conducted during regular radiology-pathology meetings at our center. The detection rates of clinically significant PCA and the proportions of clinically significant PCAs from MRI-visible and MRI-invisible PCAs were calculated. The performance of PI-RADSv2 for detecting clinically significant PCA was evaluated using the positive predictive value (PPV), negative predictive value (NPV), and area under the ROC curve (AUC) value.
Results:
Using a PI-RADSv2 score of 3, 4, or 5 as an MRI-visible lesion, 46.88% of clinically significant PCA lesions were detected. The PPV, NPV, and AUC were 96.77%, 45.16%, and 0.72, respectively. Tumor volume and secondary Gleason grade showed a statistically significant difference between MRI-visible and MRI-invisible clinically significant PCAs.
Conclusion:
Multiparametric MRI with PI-RADSv2 missed a considerable number of clinically significant PCA lesions in this per-lesion analysis, causing a relatively low NPV and diagnostic performance compared with previous per-patient studies. However, the high PPV indicates that multiparametric MRI with PI-RADSv2 may be useful for follow-up of active surveillance and planning focal therapy.
Related Concept Videos
Data Reporting and Recording
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity,...
Correlations
Statistical Software for Data Analysis and Clinical Trials
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:

