Computer navigation for total knee arthroplasty achieves better postoperative alignment compared to conventional and
Eduardo M Suero1, Ulrich Lueke1, Timo Stuebig1
1Trauma Department, Hannover Medical School, Carl-Neuberg-Strasse 1, 30625 Hannover, Germany.
Background:
Procedure volume is an important determinant of total knee arthroplasty (TKA) outcomes. We aimed to determine whether computer navigation or patient-specific instrumentation (PSI) would improve postoperative alignment in a low-volume setting.
Hypothesis:
PSI for TKA achieves better limb and implant alignment compared to conventional TKA and to computer navigated TKA.
Materials And Methods:
This is a retrospective cohort study of 385 primary TKAs (Women=59%. Mean age=67years. Mean BMI=30.1kg/m2), which were performed using conventional instrumentation (n=117; 30%), computer navigation (n=209; 54%), or patient-specific instrumentation (n=59; 15%) in a low-volume center (<50 TKAs/year). The risk of postoperative leg and implant mechanical alignment outliers in the coronal plane (>3° from neutral), average alignment and operation time were assessed.
Results:
The risk of postoperative mechanical alignment outliers (>3°) was reduced by 89% in the navigated group (4% outliers) compared to the conventional group (35%) (RR=0.11; p<0.0001). No significant improvement was observed in the PSI group (27%) (RR=0.91; p=0.772). The risk of postoperative femoral component coronal alignment outliers was reduced by 63% in the navigated group (11%) compared to the conventional group (31%) (RR=0.37; p=0.018). No significant reduction in outliers was observed in the PSI group (32%) (RR=1.08; p=0.816). There was a reduction in the risk of tibial component coronal malalignment of 66% in the navigated group (5%) compared to the conventional group (13%) (RR=0.33; p=0.070). There was a two-fold increase in the risk of tibial component alignment outliers in the PSI group (29%) (RR=1.94; p=0.110).
Discussion:
Computer navigation improved postoperative alignment in TKA. No evidence of improved alignment was seen with patient-specific instrumentation. The routine use of patient-specific instrumentation in low-volume centers is not supported by the currently available data.
Type Of Study:
Retrospective cohort study. Level IV.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers