Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Drug Dosing: Geriatric Patients01:15

Drug Dosing: Geriatric Patients

278
Elderly individuals encompass a diverse population with varying degrees of age-related physiological changes. Defining the elderly presents challenges, as the geriatric population is often arbitrarily categorized as individuals older than 65. However, many individuals in this group lead active and healthy lives, with an increasing number surpassing 85 years and falling into the older elderly category. Physiological changes associated with aging impact performance capacity and homeostatic...
278
Drug Dosing: Obese Patients01:21

Drug Dosing: Obese Patients

269
In the United States, obesity is a prominent concern. It is linked to heightened mortality rates due to increased occurrences of conditions such as hypertension, atherosclerosis, coronary artery disease, and diabetes compared to nonobese individuals. A patient is classified as obese if their actual body weight surpasses the ideal or desirable body weight by 20%, based on Metropolitan Life Insurance Company data. Ideal body weights consider average weights and heights for males and females...
269
Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

320
Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
320
Weighted Mean00:57

Weighted Mean

6.5K
While taking the arithmetic, geometric, or harmonic mean of a sample data set, equal importance is assigned to all the data points. However, all the values may not always be equally important in some data sets. An intrinsic bias might make it more important to give more weightage to specific values over others.
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
6.5K
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration01:28

Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

237
Glomerular filtration rate (GFR) can be estimated from serum creatinine using the modification of diet in renal disease (MDRD) formula or the chronic kidney disease–epidemiology collaboration (CKD–EPI) equation. Both methods are widely used in clinical practice to assess kidney function and guide treatment decisions.The MDRD equation does not require weight or height measurements and is normalized to the body surface area of 1.73 m², considered the average adult surface area.
237
What are Estimates?01:06

What are Estimates?

8.9K
It isn't easy to measure a parameter such as the mean height or the mean weight of a population. So, we draw samples from the population and calculate the mean height or mean weight of the individuals in the sample. This sample data acts as a representative measure of the population parameter. These sample statistics are known as estimates. 
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
8.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Editorial: The rise of postmortem imaging in forensic radiology and paleoradiology.

Frontiers in radiology·2026
Same author

In Situ pH Determination Using <sup>1</sup>H-MRS Acetate Chemical Shift for Noninvasive Postmortem Examinations.

NMR in biomedicine·2026
Same author

The effect of longitudinal loading under weight-bearing conditions on ballistic long bone fracture patterns - an experimental study on porcine femora.

International journal of legal medicine·2026
Same author

Advancing forensic medicine through AI-based injury detection: innovation as the catalyst for forensic 3D avatars and translation as the pathway toward courtroom-grade digital twins.

Forensic science, medicine, and pathology·2026
Same author

Ketamine-induced changes in accumbal glutamate and their association with altered states of consciousness.

Brain research bulletin·2026
Same author

Stereotactic rodent-to-human approximation of the mesencephalic cuneiform nucleus to guide deep brain stimulation.

Brain stimulation·2026
Same journal

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction.

European radiology experimental·2026
Same journal

Radiologic response assessment in patients with desmoid-type fibromatosis treated with percutaneous cryoablation.

European radiology experimental·2026
Same journal

Technical architecture for integrating vision-language models with DICOM viewers.

European radiology experimental·2026
Same journal

Real-time 3-T MRI of peroneal tendon motion during active ankle movement: feasibility and image quality.

European radiology experimental·2026
Same journal

DECT-based stratification of nonocclusive mesenteric ischemia using bowel-wall iodine concentration: a prospective single-center cohort.

European radiology experimental·2026
Same journal

Feasibility of deep learning-accelerated ultrafast T1-weighted VIBE Dixon imaging of the pelvis for screening of metastases in prostate MRI.

European radiology experimental·2026
See all related articles

Related Experiment Video

Updated: Feb 11, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

10.5K

A new method for estimating patient body weight using CT dose modulation data.

Dominic Gascho1, Lucia Ganzoni1, Philippe Kolly2

  • 11Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, 8057 Zurich, Switzerland.

European Radiology Experimental
|May 1, 2018
PubMed
Summary
This summary is machine-generated.

Estimating body weight (BW) using computed tomography (CT) dose modulation is a reliable method. This technique offers a rapid and accurate approach for BW estimation, especially in emergency care settings.

Keywords:
Body weightComputed tomographyDose modulationEmergency radiologyVirtopsy

More Related Videos

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
14:08

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images

Published on: April 13, 2013

43.6K
Whole-body PET/MRI of Pediatric Patients: The Details That Matter
10:02

Whole-body PET/MRI of Pediatric Patients: The Details That Matter

Published on: December 19, 2017

15.4K

Related Experiment Videos

Last Updated: Feb 11, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

10.5K
Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
14:08

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images

Published on: April 13, 2013

43.6K
Whole-body PET/MRI of Pediatric Patients: The Details That Matter
10:02

Whole-body PET/MRI of Pediatric Patients: The Details That Matter

Published on: December 19, 2017

15.4K

Area of Science:

  • Medical Imaging
  • Radiology
  • Forensic Science

Background:

  • Body weight (BW) is crucial in emergency care, but current estimation methods are unreliable.
  • Visual and physical assessments of BW lack accuracy.
  • A novel method for BW estimation using computed tomography (CT) effective mAs (mAseff) has been developed.

Purpose of the Study:

  • To develop and validate a method for estimating body weight (BW) using computed tomography (CT) effective mAs (mAseff).
  • To establish a reliable and rapid technique for BW estimation applicable in clinical and emergency settings.

Main Methods:

  • Correlated mAseff from CT examinations with the BW of 329 decedents.
  • Utilized linear regression analysis to derive an equation for BW estimation.
  • Validated the equation on a separate group of 125 decedents using Pearson correlation and t-test statistics.

Main Results:

  • A strong overall correlation (r=0.931) was found between mAseff and BW.
  • The derived equation demonstrated high accuracy across different postmortem intervals (PMI) and sexes.
  • Validation confirmed a strong correlation (r=0.969) between measured and predicted BW, with no significant differences.

Conclusions:

  • CT dose modulation provides a rapid and reliable method for estimating body weight (BW).
  • This technique shows significant potential for clinical application, particularly in emergency medical situations.
  • The developed method offers an accurate alternative to unreliable visual/physical BW estimation techniques.