Related Experiment Video
Updated: Feb 11, 2026

Author Spotlight: Engineering Molecular Tools for Disease Detection and Imaging
Published on: December 8, 2023
Electrochemical immunosensor for differential diagnostic of Wuchereria bancrofti using a synthetic peptide
Isis C Prado1, Verônica G Mendes2, André L A Souza3
1Center for Technological Development in Health (CDTS)/National Institute of Science and Technology for Innovation on Neglected Diseases (INCT-IDN), FIOCRUZ, Rio de Janeiro, RJ, Brazil.
Abstract:
Lymphatic filariasis (LF) is a neglected tropical disease transmitted by mosquitoes and the second cause of permanent disability leading to a significant morbidity and mortality rate. Previously, we have identified epitopes of the filarial abundant larval transcript-2 (ALT-2) protein using a microarray mapping. In this study, one of the epitopes (Wb/ALT2-A5) was used to construct an electrochemical immunosensor. Electrochemical technique of cyclic voltammetry was performed for detecting the signal generated by the interaction between the (Wb/ALT2-A5) peptide and circulating antibodies of serum human samples. (Wb/ALT2-A5) epitope antigens were successfully immobilized on the working electrode of a screen-printed carbon electrode (SPCE) by their amine groups via chitosan film by coupling with glutaraldehyde as crosslinker. After the sensor ready, a pool of human sera infected with Wuchereria bancrofti was added to its surface. Electrochemical responses were generated by applying a potential of - 0.6 to 0.6 V, scan rate of 0.025 V/s. A detection limit of 5.0 µg mL-1 for the synthetic peptides (Wb/ALT2-A5) and 0.002 µg mL-1 for human serum, with a sensitivity of 1.86 µA. The performance of this assay was successfully tested in human serum samples from infected and healthy patients. Thus, this proposed immunosensor, which is able to identify circulating antibodies, can be applied to the diagnosis of the W. bancrofti parasitic disease.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Peptide Bonds
Synthetic Biology
Golden rice
Golden rice is a genetically modified...
Synthetic Disvision of Polynomials
Interfacial Electrochemical Methods: Overview
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...

