Related Experiment Video
Updated: Feb 11, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Study on the adiabaticity criterion of the thermally-guided very-large-mode-area fiber
Abstract:
The adiabaticity criterion of the thermally-guided very-large-mode-area (TG VLMA) fiber is presented based on the mode-coupling theory firstly, to the best of our knowledge. The requirement for the adiabatic propagation of fundamental mode is discussed systematically. It is revealed that the pump absorption plays the most important role and the adiabaticity criterion can be met as long as it is small enough. Then, the effects of the configuration parameters of TG VLMA fiber on the up-limitation of pump absorption for the adiabaticity criterion are investigated. It is found that for the straight TG VLMA fiber, reducing the initial refraction index and inner-cladding diameter and utilizing the bi-directional pumping scheme are beneficial to the adiabatic propagation of fundamental mode. The bent TG VLMA fiber is also studied. It is found that the bent fiber is much more difficult to meet the adiabaticity criterion than the straight one. The results show that even with the 100-cm bend radius, the pump absorption should be smaller than 1 dB/m to meet the adiabaticity criterion. It is suggested that enlarging the core-to-cladding ratio can be helpful for loosening the adiabaticity criterion of bent TG VLMA fiber. These pertinent results can provide significant guidance for understanding and designing the TG VLMA fiber and pertinent lasers and amplifiers.
More Related Videos
14:18Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
08:48Low-cost Custom Fabrication and Mode-locked Operation of an All-normal-dispersion Femtosecond Fiber Laser for Multiphoton Microscopy
Published on: November 22, 2019
Related Concept Videos
Work Done in an Adiabatic Process
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Potential-Energy Criterion for Equilibrium